EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluation of Cone Beam Computed Tomography Resolution, 3D Printing Resolution and Drilling Depth on Drilling Accuracy in Guided Endodontics: An In-Vitro Study

Marine Hénaut, Maarten Meire, Jérôme Vandomme, Lieven Robberecht

European Endodontic Journal · 14.03.2025 · 10 (2) · 127-133

DOI: 10.14744/eej.2024.57441 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Endodontic Journal, online erschienen am 14.03.2025. Verfasst von Marine Hénaut und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry and Endodontics, University of Lille, Faculty of Odontology, Inserm, CHU Lille, Lille, France. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Printing, Three-Dimensional, Surgery, Computer-Assisted, Endodontics. Die Arbeit wurde bisher 3-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to evaluate the influence of cone-beam computed tomography (CBCT) resolution, 3D printing resolution, and drilling depth on drilling accuracy in guided endodontic access.

Methods

Fifty-six printed canines were designed, fabricated, and mounted in maxillary arch models. Preoperative CBCT and 3D surface scan were matched and used to design a surgical guide with different planning parameters: 1) reference (high-resolution CBCT (80 µm) and 3D printing (50 µm), shallow drilling (14 mm)), 2) low-resolution CBCT (120 µm), 3) low-resolution 3D printing (100 µm) and 4) deep drilling (high-resolution CBCT (80 µm) and 3D printing (50 µm), deep drilling (21 mm)). Guided access into the printed canines was performed in a simulated clinical setting. A postoperative CBCT was matched with the planning data in order to determine the angular and linear (total, mesiodistal, buccolingual and depth) deviation between the planned and performed cavities. Mann-Whitney test was used to analyse differences between the reference group and each test group.

Results

Angular, total linear and buccolingual deviations were significantly higher in the low-resolution CBCT group than in the reference group (median: 3.10° and 2.0° (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyPrinting, Three-DimensionalSurgery, Computer-AssistedEndodonticsHumansIn Vitro TechniquesCuspidModels, Dental

Autor:innen und Institutionen

  • Department of Restorative Dentistry and Endodontics, University of Lille, Faculty of Odontology, Inserm, CHU Lille, Lille, France.
  • Department of Oral Health Sciences, Ghent University, Section of Endodontology, Ghent, Belgium.
  • Department of Prosthodontics, University of Lille, Faculty of Odontology, Inserm, CHU Lille, Lille, France.

Zitieren

APA

Hénaut, M., Meire, M., Vandomme, J., & Robberecht, L. (2025). Evaluation of Cone Beam Computed Tomography Resolution, 3D Printing Resolution and Drilling Depth on Drilling Accuracy in Guided Endodontics: An In-Vitro Study. European Endodontic Journal, 10(2), 127-133. https://doi.org/10.14744/eej.2024.57441

Vancouver

Hénaut M, Meire M, Vandomme J, Robberecht L. Evaluation of Cone Beam Computed Tomography Resolution, 3D Printing Resolution and Drilling Depth on Drilling Accuracy in Guided Endodontics: An In-Vitro Study. European Endodontic Journal. 2025;10(2):127-133. doi:10.14744/eej.2024.57441

BibTeX
@article{Hnaut2025,
  author = {Hénaut, Marine and Meire, Maarten and Vandomme, Jérôme and Robberecht, Lieven},
  title = {Evaluation of Cone Beam Computed Tomography Resolution, 3D Printing Resolution and Drilling Depth on Drilling Accuracy in Guided Endodontics: An In-Vitro Study},
  journal = {European Endodontic Journal},
  year = {2025},
  volume = {10},
  number = {2},
  pages = {127--133},
  doi = {10.14744/eej.2024.57441}
}
Kostenlos starten →