Serial Custom 3D-Printed Nostril Retainers After Unilateral Cleft Lip Repair in Infants: A Comparative Report of Two Cases
Journal of Medical Cases · 2027 · 18 · e5440
DOI: 10.14740/jmc5440 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Cases, 2027. Verfasst von Dieu Hong Dinh und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Postoperative nasal support may help maintain the contour established by cleft lip repair, but the contribution of an individual appliance protocol requires careful evaluation. This report describes sequential use of custom bilateral nostril retainers and compares the clinical course with that of an infant treated without retention. Two 3-month-old infants, one boy and one girl, with complete left unilateral cleft lip and palate underwent Fisher lip and nasal repair by the same surgeon. Neither had received presurgical molding. Random allocation determined postoperative management with or without retention. For the intervention infant, an immediate postoperative nasal impression was digitized to design six sequential bilateral retainers incorporating staged enlargement and later-stage mirroring of the non-cleft side. The appliances were fabricated using TFDH resin and a UNIZ UBEE printer. Retention began after suture removal at postoperative week 1 and continued for approximately 6 months. Clinical and photographic assessments were performed at 1 week, 3 months, and 6 months. At the later reviews, cleft-side alar collapse appeared more pronounced in the infant without retention. Initial columellar blanching in the intervention infant resolved within approximately 20–30 s; no local allergic reaction or appliance loosening was reported. Outcomes were assessed qualitatively, without standardized nasal measurements. This two-case report illustrates the clinical implementation of serial custom bilateral nostril retainers following unilateral cleft lip repair. The observed difference in postoperative alar contour provides a basis for further investigation but cannot establish a causal benefit of retention. Larger studies with objective measurements, standardized photography, and follow-up after appliance discontinuation are needed to evaluate effectiveness and longer-term safety.
Zitieren
APA
Dinh, D. H., Trinh, D. H., Dang, T. H., Nguyen, T. M. H., Dang, H. H., & Hoang, V. (2027). Serial Custom 3D-Printed Nostril Retainers After Unilateral Cleft Lip Repair in Infants: A Comparative Report of Two Cases. Journal of Medical Cases, 18, e5440. https://doi.org/10.14740/jmc5440
Vancouver
Dinh DH, Trinh DH, Dang TH, Nguyen TMH, Dang HH, Hoang V. Serial Custom 3D-Printed Nostril Retainers After Unilateral Cleft Lip Repair in Infants: A Comparative Report of Two Cases. Journal of Medical Cases. 2027;18:e5440. doi:10.14740/jmc5440
BibTeX
@article{Dinh2027,
author = {Dinh, Dieu Hong and Trinh, Dinh Hai and Dang, Trieu Hung and Nguyen, Thi Minh Huyen and Dang, Hoang Hiep and Hoang, Viet},
title = {Serial Custom 3D-Printed Nostril Retainers After Unilateral Cleft Lip Repair in Infants: A Comparative Report of Two Cases},
journal = {Journal of Medical Cases},
year = {2027},
volume = {18},
pages = {e5440},
doi = {10.14740/jmc5440}
}