Kurz gefasst
Fachartikel in der Zeitschrift 国际护理研究, 2014. Verfasst von Hong-ying YI. Die Arbeit wurde bisher 1-mal zitiert (Crossref).
Abstract (Originalsprache)
Objective
To explore the causes of unplanned extubation of deep venous catheter in the Department of Neurosurgery and nursing countermeasures.
Methods
Retrospectively analyze the causes of unplanned extubation of deep venous catheter in neurosurgery department in 2012.
Results
228 cases of deep venous catheter were collected, 28 cases of unplanned extubation of deep venous catheter, 15 cases of suspected infection, accidental extubation in 5 cases, puncture liquid leaking in 3 cases and skin allergy in 2 cases.
Conclusion
Nursing that did not follow the operating rule may result in unplanned removal of deep venous catheter during the period of indwelling deep venous catheter. Training of nursing staff, strict implementation of nursing operation rules and effective intervention of adverse factors can decrease the incidence of unplanned extubation.
Zitieren
APA
YI, H. (2014). 神经外科非计划性拔除深静脉导管的原因分析及护理对策. 国际护理研究. https://doi.org/10.14725/gjnr.v2n5a682
Vancouver
YI H. 神经外科非计划性拔除深静脉导管的原因分析及护理对策. 国际护理研究. 2014. doi:10.14725/gjnr.v2n5a682
BibTeX
@article{YI2014,
author = {YI, Hong-ying},
title = {神经外科非计划性拔除深静脉导管的原因分析及护理对策},
journal = {国际护理研究},
year = {2014},
doi = {10.14725/gjnr.v2n5a682}
}