Analysis of influencing factors of corneal edema after phacoemulsification for diabetic cataract
Cellular and Molecular Biology · 30.04.2023 · 69 (4) · 164-171
DOI: 10.14715/cmb/2023.69.4.26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Cellular and Molecular Biology, online erschienen am 30.04.2023. Verfasst von Zhifu Jing und 6 weiteren Autor:innen. Beteiligte Einrichtung: Myopia Laser Operation Department, Ai Yan Ophthalmology Hospital-HAN DAN, Handan, 056008, China. jingzhifu2022@163.com. Hauptthemen laut MEDLINE: Phacoemulsification, Corneal Edema, Cataract, Diabetes Mellitus. Die Arbeit wurde bisher 8-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
The paper aimed to explore the influence factors of corneal edema after phacoemulsification for diabetic cataracts. For this aim, 80 patients (80 eyes) with senile cataracts who underwent phacoemulsification implantation in our hospital from August 2021 to January 2022 were included in this study, including 39 males (48.75%) and 41 females (51.25%), with an average age of 70.35±5.22 years. The OCT system during ophthalmology was used to capture corneal OCT images in the center of the cornea in real time before the phacoemulsification (the phacoemulsification probe just entered the anterior chamber after the balanced saline left the separated nucleus), at the end of phacoemulsification (when the phacoemulsification ultrasound probe was still in the anterior chamber and the perfusion pressure did not change compared with that in the previous step), at the end of perfusion aspiration (after the perfusion aspiration probe left the anterior chamber), and after surgery (after the watertight incision is closed). The corneal thickness was measured at each time point using Photoshop software. AL, curvature and ACD were measured using IOL-Master bio-measurement technology, and ACD referred to the distance between the front surface of the cornea and the front surface of the lens. Endothelial cell density was measured using CIM-530 non-contact mirror microscope. A handheld rebound tonometer was used to measure intraocular pressure and optical coherence tomography was used to assess the macular area of the fundus. Fundus photography was performed with a non-diffuse fundus camera. The results indicated that the preoperative corneal thickness was 514.35±29.62 μm, and the average corneal thickness at the end of the operation was 535.26±30.29μm, which was increased by 20.91±1.67 μm compared with that before operation (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Myopia Laser Operation Department, Ai Yan Ophthalmology Hospital-HAN DAN, Handan, 056008, China. jingzhifu2022@163.com.
- Myopia Laser Operation Department, Ai Yan Ophthalmology Hospital-HAN DAN, Handan, 056008, China. haojunhua2022@163.com.
- Scientific Research Group, Eye Care Hospital Management (Beijing) Co., Ltd., Beijing, 100062, China. abainier@163.com.
- Myopia Laser Operation Department, Ai Yan Ophthalmology Hospital-HAN DAN, Handan, 056008, China. m18937815551@163.com.
- Myopia Laser Operation Department, Ai Yan Ophthalmology Hospital-HAN DAN, Handan, 056008, China. jiaxinlianghandan@126.com.
- Myopia Laser Operation Department, Ai Yan Ophthalmology Hospital-HAN DAN, Handan, 056008, China. lzq15383181716@163.com.
Zitieren
APA
Jing, Z., Hao, J., Sun, L., Zhao, X., Jia, X., Liu, Z., & Zhang, K. (2023). Analysis of influencing factors of corneal edema after phacoemulsification for diabetic cataract. Cellular and Molecular Biology, 69(4), 164-171. https://doi.org/10.14715/cmb/2023.69.4.26
Vancouver
Jing Z, Hao J, Sun L, Zhao X, Jia X, Liu Z, et al. Analysis of influencing factors of corneal edema after phacoemulsification for diabetic cataract. Cellular and Molecular Biology. 2023;69(4):164-171. doi:10.14715/cmb/2023.69.4.26
BibTeX
@article{Jing2023,
author = {Jing, Zhifu and Hao, Junhua and Sun, Lijuan and Zhao, Xiaoli and Jia, Xinliang and Liu, Zhiqiang and Zhang, Kun},
title = {Analysis of influencing factors of corneal edema after phacoemulsification for diabetic cataract},
journal = {Cellular and Molecular Biology},
year = {2023},
volume = {69},
number = {4},
pages = {164--171},
doi = {10.14715/cmb/2023.69.4.26}
}
EUVIMED