Experimental Evaluation of Normal Concrete Performance with the Addition of Retarders and High-Range Water Reducers Under Conditions of Delayed Compaction

Indriyani Puluhulawa, Ananda Nitania, Alamsyah Alamsyah

MEDIA KOMUNIKASI TEKNIK SIPIL · 20.10.2026 · 32 (1) · 143-154

DOI: 10.14710/mkts.v32i1.74423 ↗

Kurz gefasst

Fachartikel in der Zeitschrift MEDIA KOMUNIKASI TEKNIK SIPIL, online erschienen am 20.10.2026. Verfasst von Indriyani Puluhulawa und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Delays in concrete compaction frequently occur in construction due to transportation, equipment, or site constraints, potentially reducing concrete performance. This study evaluates the effect of a retarder (Sika Plastocrete RT6 Plus) and a high-range water-reducing admixture (HRWR, Grolen HP-19R) on the workability, setting time, and compressive strength of normal concrete subjected to compaction delays of up to 120 min. Four concrete mixtures were investigated: control concrete, concrete with 0.3% retarder, concrete with 0.4% HRWR, and concrete containing a combination of both admixtures. The combined admixture significantly prolonged the initial and final setting times while maintaining workability during delayed compaction. The mixture containing 0.3% retarder and 0.4% HRWR retained a slump above 285 mm and achieved a compressive strength of approximately 32 MPa after 60 min of delay. Although slump remained relatively high after longer delays, compressive strength gradually decreased, indicating that prolonged delay adversely affected hydration efficiency. These findings demonstrate that the optimized combination of retarder and HRWR improves concrete performance under delayed compaction and provides practical guidance for concrete mix design in construction projects requiring extended workability.

Zitieren

APA

Puluhulawa, I., Nitania, A., & Alamsyah, A. (2026). Experimental Evaluation of Normal Concrete Performance with the Addition of Retarders and High-Range Water Reducers Under Conditions of Delayed Compaction. MEDIA KOMUNIKASI TEKNIK SIPIL, 32(1), 143-154. https://doi.org/10.14710/mkts.v32i1.74423

Vancouver

Puluhulawa I, Nitania A, Alamsyah A. Experimental Evaluation of Normal Concrete Performance with the Addition of Retarders and High-Range Water Reducers Under Conditions of Delayed Compaction. MEDIA KOMUNIKASI TEKNIK SIPIL. 2026;32(1):143-154. doi:10.14710/mkts.v32i1.74423

BibTeX
@article{Puluhulawa2026,
  author = {Puluhulawa, Indriyani and Nitania, Ananda and Alamsyah, Alamsyah},
  title = {Experimental Evaluation of Normal Concrete Performance with the Addition of Retarders and High-Range Water Reducers Under Conditions of Delayed Compaction},
  journal = {MEDIA KOMUNIKASI TEKNIK SIPIL},
  year = {2026},
  volume = {32},
  number = {1},
  pages = {143--154},
  doi = {10.14710/mkts.v32i1.74423}
}
Kostenlos starten →