EUVIMEDEUVIMED entdecken
Crossref

IN VIVO LONG-TERM FIXATION OF UNLOADED PEDICLE SCREWS: MECHANICAL AND HISTOLOGICAL STUDIES OF THE INTERFACE IN SHEEP

Charles-Hilaire Rivard, Souad Rhalmi, Christine Coillard

Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika) · 30.12.2004 · (4) · 107-114

DOI: 10.14531/ss2004.4.107-114 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika), online erschienen am 30.12.2004. Verfasst von Charles-Hilaire Rivard und 2 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Pedicle screws were machined from five different materials used in orthopaedic surgery. The bone tissue reaction to these materials implanted as unloaded pedicle screws was investigated mechanically and histologically.

Methods

Ten pedicle screws of the same material were implanted per sheep in the lumbar region from L1 to L5. The bone tissue reaction to Ti alloy, c.p.Ti grade 1 and 4, 316L stainless steel and Vitallium fixation (unloaded pedicle screws) was evaluated mechanically and histologically.

Results

Ti alloy, c.p.Ti grade 4 and 316L stainless steel screws showed significant pull-out strength as compared to Vitallium and c.p. Ti grade 1 screws (p < 0.005). Histological analysis revealed direct bone contact to c.p. Ti and Ti alloy screws and the formation of new compact bone around the implant within the cancellous bone. The 316L stainless steel histological sections displayed few areas with direct bone contact, whereas Vitallium sections showed bone resorption all around the implants.

Conclusions

The five materials (screws) showed great pull-out forces but better osteointegration was observed with c.p.Ti and Ti alloy screws compared with Vitallium and 316L screws. Even if the 316L stainless steel material showed high pull-out strength, histologically its osteointegration was not as relevant as titanium material. Therefore, 316L stainless steel is more susceptible to the loosening than titanium.

Zitieren

APA

Rivard, C., Rhalmi, S., & Coillard, C. (2004). IN VIVO LONG-TERM FIXATION OF UNLOADED PEDICLE SCREWS: MECHANICAL AND HISTOLOGICAL STUDIES OF THE INTERFACE IN SHEEP. Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika), 107-114. https://doi.org/10.14531/ss2004.4.107-114

Vancouver

Rivard C, Rhalmi S, Coillard C. IN VIVO LONG-TERM FIXATION OF UNLOADED PEDICLE SCREWS: MECHANICAL AND HISTOLOGICAL STUDIES OF THE INTERFACE IN SHEEP. Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika). 2004:107-114. doi:10.14531/ss2004.4.107-114

BibTeX
@article{Rivard2004,
  author = {Rivard, Charles-Hilaire and Rhalmi, Souad and Coillard, Christine},
  title = {IN VIVO LONG-TERM FIXATION OF UNLOADED PEDICLE SCREWS: MECHANICAL AND HISTOLOGICAL STUDIES OF THE INTERFACE IN SHEEP},
  journal = {Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika)},
  year = {2004},
  number = {4},
  pages = {107--114},
  doi = {10.14531/ss2004.4.107-114}
}
Kostenlos starten →