STUDY ON A SYSTEM FOR CONTACTLESS CONTROL OF OVERHEAD LINES UNDER CONDITIONS OF LOW POWER QUALITY

A.M. Bramm, A.I. Khalyasmaa, S.F. Sarapulov, V.P. Metelkov

Bulletin of the South Ural State University series "Power Engineering" · 2026 · 26 (1) · 24-31

DOI: 10.14529/power260103 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of the South Ural State University series "Power Engineering", 2026. Verfasst von A.M. Bramm und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper analyzes the performance of a contactless control system for medium-voltage overhead lines, designed to detect single-phase ground faults (SGFs) by analyzing electromagnetic field signals from the line. The system comprises two independent measurement channels: contactless inductive sensors (recording the magnetic component of the field), contactless capacitive sensors (recording the electric component of the field), and a software algorithm that detects the moment of mode change by the change in the energy of the fundamental harmonic in the sensor signals. Experimental verification is performed on a laboratory setup simulating a three-phase overhead line with an isolated neutral. The deterioration in power quality (an increase in current THD from 2.6–3.0 % to 8.6–10.7 %) is accompanied by a sharp decrease in 50 Hz power in the sensor signals (from ~ 35 % to ~ 0.45 %), which leads to a decrease in the number of sensors triggered and an increase in the detection time error. At the same time, in some experiments under low power quality conditions, the system maintains correct detection of the fault inception and clearing instants, con-firming the feasibility the fundamental applicability of contactless monitoring in non-stationary and non-sinusoidal electrical environments and sets the direction for further improving the robustness of processing algorithms.

Zitieren

APA

Bramm, A., Khalyasmaa, A., Sarapulov, S., & Metelkov, V. (2026). STUDY ON A SYSTEM FOR CONTACTLESS CONTROL OF OVERHEAD LINES UNDER CONDITIONS OF LOW POWER QUALITY. Bulletin of the South Ural State University series "Power Engineering", 26(1), 24-31. https://doi.org/10.14529/power260103

Vancouver

Bramm A, Khalyasmaa A, Sarapulov S, Metelkov V. STUDY ON A SYSTEM FOR CONTACTLESS CONTROL OF OVERHEAD LINES UNDER CONDITIONS OF LOW POWER QUALITY. Bulletin of the South Ural State University series "Power Engineering". 2026;26(1):24-31. doi:10.14529/power260103

BibTeX
@article{Bramm2026,
  author = {Bramm, A.M. and Khalyasmaa, A.I. and Sarapulov, S.F. and Metelkov, V.P.},
  title = {STUDY ON A SYSTEM FOR CONTACTLESS CONTROL OF OVERHEAD LINES UNDER CONDITIONS OF LOW POWER QUALITY},
  journal = {Bulletin of the South Ural State University series "Power Engineering"},
  year = {2026},
  volume = {26},
  number = {1},
  pages = {24--31},
  doi = {10.14529/power260103}
}
Kostenlos starten →