EUVIMEDEUVIMED entdecken
Crossref

Industrial Noise Measurement and Noise Contour Mapping: A Case Study in Power Plant, Rayong Province, Thailand

Somboon Chaiprakarn, Taweesak Thongsan

Journal of Health Science and Alternative Medicine · 30.04.2024

DOI: 10.14456/jhsam.2024.1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Health Science and Alternative Medicine, erschienen am 30.04.2024. Verfasst von Somboon Chaiprakarn und 1 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study aimed to assess the noise level in a working environment and to illustrate noise contour maps to define areas for wearing personal protective equipment in the electricity production process of the power plant in Rayong province.

Methods

The measurement of noise levels was divided into all areas, a total of 1,700 points, using the sound level meter model NL-42EX (Class2) standardized by IEC61672 Type2, ANSI S1.4, JISC1509-1. Then, the results were illustrated to create the noise contour map and define areas for wearing personal protective equipment.

Results

Compared to the standard noise levels that allowed employees to average receive throughout a day's work in 2018 from the Department of Labor Protection and Welfare, 45 points were detected over the standard level at 85 dB(A) (2.5 %) at the areas of machinery works continuously, steam turbines, gas turbines, steam generators, etc. Protective equipment and measures must be implemented for electricity production workers. To prevent hearing impairment, one should initially wear personal protective equipment, which can reduce noise exposure by Ear Muff. The derated NRR is 24 dB(A), and the sound level of the employee when wearing an ear muff is 65.7 dB(A), which is a safe sound level.

Conclusion

Additionally, a hearing conservation program should be implemented to comply with the legislation and reduce risks to employees' hearing performance. Keywords: Noise Measurement, Noise contour mapping, Power plant

Schlagwörter

industrial noisenoise contour mappingoccupational noise exposurepower plant workerspersonal protective equipmentearmuffshearing conservation programshearing loss preventionnoise measurement

Zitieren

APA

Chaiprakarn, S., & Thongsan, T. (2024). Industrial Noise Measurement and Noise Contour Mapping: A Case Study in Power Plant, Rayong Province, Thailand. Journal of Health Science and Alternative Medicine. https://doi.org/10.14456/jhsam.2024.1

Vancouver

Chaiprakarn S, Thongsan T. Industrial Noise Measurement and Noise Contour Mapping: A Case Study in Power Plant, Rayong Province, Thailand. Journal of Health Science and Alternative Medicine. 2024. doi:10.14456/jhsam.2024.1

BibTeX
@article{Chaiprakarn2024,
  author = {Chaiprakarn, Somboon and Thongsan, Taweesak},
  title = {Industrial Noise Measurement and Noise Contour Mapping: A Case Study in Power Plant, Rayong Province, Thailand},
  journal = {Journal of Health Science and Alternative Medicine},
  year = {2024},
  doi = {10.14456/jhsam.2024.1}
}
Kostenlos starten →