Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography
Journal of Radiation Protection and Research · 30.03.2026 · 51 (1) · 39-46
DOI: 10.14407/jrpr.2025.00241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiation Protection and Research, erschienen am 30.03.2026. Verfasst von Koji Ono und 1 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
We aimed to evaluate the effects of different incident directions on organ-absorbed doses, effective doses, and effective dose conversion coefficients for chest radiography.Materials and Methods: We constructed an examination environment for chest radiography using a Monte Carlo simulation and estimated the organ-absorbed doses and effective doses for frontal anterior–posterior (AP), frontal posterior–anterior (PA), left lateral, and right lateral radiography. The effective dose conversion coefficients were calculated using the air kerma-area product.Results and Discussion: Some organs, such as the breast, showed more than a fivefold difference in the organ-absorbed dose between AP and PA radiography. In lateral radiography, there was a large difference in the organ-absorbed doses in the abdominal region. The effective dose was approximately 30% higher for AP radiography than for PA radiography. The effective dose conversion coefficients differed between AP and PA radiography. These findings are consistent with the anatomical arrangement of organs in the human body; nevertheless, they have not been explicitly reported in previous studies.
Conclusion
It was suggested that using the PA direction of incidence in frontal radiography reduces the effective dose received by the patient. In addition, when estimating the effective dose using conversion coefficients, the estimated value may differ significantly due to differences in the direction of incidence, so the coefficients must be appropriately selected.
Zitieren
APA
Ono, K., & Asada, Y. (2026). Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography. Journal of Radiation Protection and Research, 51(1), 39-46. https://doi.org/10.14407/jrpr.2025.00241
Vancouver
Ono K, Asada Y. Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography. Journal of Radiation Protection and Research. 2026;51(1):39-46. doi:10.14407/jrpr.2025.00241
BibTeX
@article{Ono2026,
author = {Ono, Koji and Asada, Yasuki},
title = {Effects of Different Incident Direction on Organ-Absorbed Doses, Effective Doses, and Effective Dose Conversion Coefficients for Chest Radiography},
journal = {Journal of Radiation Protection and Research},
year = {2026},
volume = {51},
number = {1},
pages = {39--46},
doi = {10.14407/jrpr.2025.00241}
}
EUVIMED