Carotid intima thickness assessed using high-resolution ultrasound as a structural correlate of endothelial dysfunction
Ultrasonography · 01.11.2026 · 45 (6) · 564-575
DOI: 10.14366/usg.26069 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasonography, erschienen am 01.11.2026. Verfasst von Bi-Xiao Shen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, Chin…. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Research Project on Health Care for Cadres in Jiangsu Province, Research Project of Jiangsu Province Hospital of Chinese Medicine.
Abstract (Originalsprache)
Purpose
This study evaluated the association between carotid intima thickness (cIT), measured using high-resolution ultrasound, and endothelial cell dysfunction (ECD), assessed using flow-mediated dilation (FMD), for early atherosclerosis risk assessment.
Methods
Between January and December 2024, 102 middle-aged nonsmoking participants were prospectively recruited; 66 were included in the final analysis and classified into a risk group (n=44) or control group (n=22) according to the presence or absence of at least one conventional cardiovascular risk factor. Data collected included demographic characteristics, physical measurements, laboratory findings, cIT, carotid media thickness (cMT), and carotid intima-media thickness (cIMT). After 5 minutes of forearm occlusion, brachial artery diameters were measured at baseline and at 30, 60, and 120 seconds after cuff deflation during systole and diastole, and FMD indices were calculated. Receiver operating characteristic (ROC) curve analysis was performed, with differences between the ROC curves evaluated using the Hanley-McNeil test.
Results
Compared with the control group, the risk group had greater cIT (P<0.001) and cIMT (P=0.016) and generally lower FMD indices. cMT did not differ significantly between groups (P=0.595). Among carotid ultrasound parameters, cIT showed the strongest association with atherosclerosis risk (standardized β=0.489, P<0.05) and the strongest inverse correlation with systolic FMD measured 60 seconds after cuff deflation (FMDS60; ρ=−0.689, adjusted P=0.001). In ROC analysis, cIT generally showed better performance for identifying ECD than cMT and cIMT, with a maximum area under the curve of 0.896 (P<0.001).
Conclusion
High-resolution ultrasound measurement of cIT may provide a noninvasive imaging marker of early endothelial dysfunction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, China.
- Department of Ultrasound, Jiangsu Province Geriatric Hospital, Geriatric Hospital of Nanjing Medical University, Nanjing, China.
- Department of Cardiology, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, China.
- Center of Good Clinical Practice, Affiliated Hospital of Nanjing University of Chinese Medicine, Jiangsu Province Hospital of Chinese Medicine, Nanjing, China.
Förderung
- Research Project on Health Care for Cadres in Jiangsu Province
- Research Project of Jiangsu Province Hospital of Chinese Medicine
Zitieren
APA
Shen, B. X., Zhu, Z. Q., Ma, X. H., Wang, Y. P., Jiang, X. Z., Zou, C., Gao, H., Dai, P., Wu, Y. Y., & Huang, H. (2026). Carotid intima thickness assessed using high-resolution ultrasound as a structural correlate of endothelial dysfunction. Ultrasonography, 45(6), 564-575. https://doi.org/10.14366/usg.26069
Vancouver
Shen BX, Zhu ZQ, Ma XH, Wang YP, Jiang XZ, Zou C, et al. Carotid intima thickness assessed using high-resolution ultrasound as a structural correlate of endothelial dysfunction. Ultrasonography. 2026;45(6):564-575. doi:10.14366/usg.26069
BibTeX
@article{Shen2026,
author = {Shen, Bi-Xiao and Zhu, Zheng-Qiu and Ma, Xue-Hui and Wang, Yin-Ping and Jiang, Xue-Zhong and Zou, Chong and Gao, Hui and Dai, Ping and Wu, Yi-Yun and Huang, Hui},
title = {Carotid intima thickness assessed using high-resolution ultrasound as a structural correlate of endothelial dysfunction},
journal = {Ultrasonography},
year = {2026},
volume = {45},
number = {6},
pages = {564--575},
doi = {10.14366/usg.26069}
}
EUVIMED