Comprehensive ultrasonographic evaluation of normal and fibrotic kidneys in a mouse model with an ultra-high-frequency transducer
Ultrasonography · 01.09.2024 · 43 (5) · 314-326
DOI: 10.14366/usg.24024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasonography, erschienen am 01.09.2024. Verfasst von Myoung Seok Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul National University Boramae Medical Center, Seoul, Korea. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: National Research Foundation of Korea, Ministry of Education, Seoul National University Boramae Medical Center.
Abstract (Originalsprache)
Purpose
This study aimed to establish baseline morphological and functional data for normal mouse kidneys via a clinical 33 MHz ultra-high-frequency (UHF) transducer, compare the data with the findings from fibrotic mice, and assess correlations between ultrasonography (US) parameters and fibrosis-related markers.
Methods
This retrospective study aggregated data from three separate experiments (obstructive nephropathy, diabetic nephropathy, and acute-to-chronic kidney injury models). Morphological parameters (kidney size, parenchymal thickness [PT]) and functional (shear-wave speed [SWS], stiffness, resistive index [RI], and microvascular imaging-derived vascular index [VI]) were assessed and compared between normal and fibrotic mouse kidneys. Semi-quantitative histopathologic scores were calculated and molecular markers (epithelial cadherin), Collagen 1A1 [Col1A1], transforming growth factor-β, and α-smooth muscle actin [α-SMA]) were evaluated using western blots. Correlations with US parameters were explored.
Results
Clinical UHF US successfully imaged the kidneys of the experimental mice. A three-layer configuration was prevalent in the normal mouse kidney parenchyma (34/35) but was blurred in most fibrotic mouse kidneys (33/40). US parameters, including size (11.14 vs. 10.70 mm), PT (2.07 vs. 1.24 mm), RI (0.64 vs. 0.77), VI (22.55% vs. 11.47%, only for non-obstructive kidneys), SWS (1.67 vs. 2.06 m/s), and stiffness (8.23 vs. 12.92 kPa), showed significant differences between normal and fibrotic kidneys (P<0.001). These parameters also demonstrated strong discriminative ability in receiver operating characteristic curve analysis (area under the curve, 0.76 to 0.95; P<0.001). PT, VI, and RI were significantly correlated with histological fibrosis markers (ρ=-0.64 to -0.68 for PT and VI, ρ=0.71-0.76 for RI, P<0.001). VI exhibited strong negative correlations with Col1A1 (ρ=-0.76, P=0.006) and α-SMA (ρ=-0.75, P=0.009).
Conclusion
Clinical UHF US effectively distinguished normal and fibrotic mouse kidneys, indicating the potential of US parameters, notably VI, as noninvasive markers for tracking fibrosis initiation and progression in mouse kidney fibrosis models.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Seoul National University Boramae Medical Center, Seoul, Korea.
- Department of Radiology, Seoul National University Hospital, Seoul, Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, Korea.
- Department of Internal Medicine, Seoul National University Boramae Medical Center, Seoul, Korea.
- Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Korea.
- Translational Medicine Major, Seoul National University College of Medicine, Seoul, Korea.
Förderung
- National Research Foundation of Korea
- Ministry of Education
- Seoul National University Boramae Medical Center
- Korean Fund for Regenerative Medicine
- Ministry of Science and ICT
- Ministry of Health and Welfare
Zitieren
APA
Lee, M. S., Cho, J. Y., Moon, M. H., Lee, J., Lee, J. P., Shin, N., Jin, W., & Cho, A. (2024). Comprehensive ultrasonographic evaluation of normal and fibrotic kidneys in a mouse model with an ultra-high-frequency transducer. Ultrasonography, 43(5), 314-326. https://doi.org/10.14366/usg.24024
Vancouver
Lee MS, Cho JY, Moon MH, Lee J, Lee JP, Shin N, et al. Comprehensive ultrasonographic evaluation of normal and fibrotic kidneys in a mouse model with an ultra-high-frequency transducer. Ultrasonography. 2024;43(5):314-326. doi:10.14366/usg.24024
BibTeX
@article{Lee2024,
author = {Lee, Myoung Seok and Cho, Jeong Yeon and Moon, Min Hoan and Lee, Jeonghwan and Lee, Jung Pyo and Shin, Nayeon and Jin, Wencheng and Cho, Ara},
title = {Comprehensive ultrasonographic evaluation of normal and fibrotic kidneys in a mouse model with an ultra-high-frequency transducer},
journal = {Ultrasonography},
year = {2024},
volume = {43},
number = {5},
pages = {314--326},
doi = {10.14366/usg.24024}
}
EUVIMED