Electron Energy Distribution for a Research Electron LINAC

Heuijin Lim, Manwoo Lee, Jungyu Yi, Sang Koo Kang, Me Young Kim, Dong Hyeok Jeong

Progress in Medical Physics · 2017

DOI: 10.14316/pmp.2017.28.2.49 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Progress in Medical Physics, 2017. Verfasst von Heuijin Lim und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministry of Science, ICT and Future Planning.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A study on the development of a medical linear accelerator (LINAC) has been actively conducted by a research center in Korea. The researchers reported on the development of a 4-MeV compact LINAC and electron beam output dose in 2015, as well as electrical and dosimetry characteristics of the electron LINAC with increased energy to 6 MeV in 2016. Currently, studies on performance improvements in high-energy accelerator tubes, pulse modulators, and control systems have been underway to develop an optimal therapeutic radiation source. Although it is important to determine the electron energy or energy distribution generated in the LINAC in terms of the development and operation of a medical electron LINAC, it is highly difficult to construct an energy analysis system such as a magnetic mass spectrometer on a small scale for a laboratory environment. Thus, it is more practical to apply a method that predicts only the mean energy and most probable energy from the measured depth dose ratio, as reported previously. Although these two energy parameters are important in measuring the absorbed dose in terms of clinical viewpoints, their energy distributions may not be important. Nonetheless, an energy distribution needs to be obtained in order to determine the characteristics and performance of accelerators from the viewpoint of the development of an accelerator. This can also be important data for research on devices such as a bending magnet. The present study aims to calculate an energy distribution of electron beams in the developed 6-MeV electron LINAC using a numerical analysis method. The present method obtains a combination of depth dose ratio that is well matched with the measured depth dose data through iterative numerical operations via computer programs using monoenergetic depth dose data. This approach was proposed by Kaver et al. in 1982, and Lee and Jeong applied this method to acquire the energy distribution of four types of electron beam energy in a medical LINAC Progress in Medical Physics 28(2), June 2017 https://doi.org/10.14316/pmp.2017.28.2.49 pISSN 2508-4445, eISSN 2508-4453

Förderung

  • Ministry of Science, ICT and Future Planning

Zitieren

APA

Lim, H., Lee, M., Yi, J., Kang, S. K., Kim, M. Y., & Jeong, D. H. (2017). Electron Energy Distribution for a Research Electron LINAC. Progress in Medical Physics. https://doi.org/10.14316/pmp.2017.28.2.49

Vancouver

Lim H, Lee M, Yi J, Kang SK, Kim MY, Jeong DH. Electron Energy Distribution for a Research Electron LINAC. Progress in Medical Physics. 2017. doi:10.14316/pmp.2017.28.2.49

BibTeX
@article{Lim2017,
  author = {Lim, Heuijin and Lee, Manwoo and Yi, Jungyu and Kang, Sang Koo and Kim, Me Young and Jeong, Dong Hyeok},
  title = {Electron Energy Distribution for a Research Electron LINAC},
  journal = {Progress in Medical Physics},
  year = {2017},
  doi = {10.14316/pmp.2017.28.2.49}
}
Kostenlos starten →