Fatigue fracture of the Logica cemented stem – Clinical and mechanical analysis
Lékař a technika - Clinician and Technology · 05.03.2026 · 56 · 5-11
DOI: 10.14311/ctj.2026.56.01 ↗Kurz gefasst
Fachartikel in der Zeitschrift Lékař a technika - Clinician and Technology, online erschienen am 05.03.2026. Verfasst von Marián Melišík und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Fracture of a cemented femoral stem is a relatively rare but serious complication of total hip arthroplasty (THA). This study aimed to perform a clinical and biomechanical analysis of six cases of fractured cemented stems to identify the risk factors associated with this type of failure. A retrospective analysis was conducted on six patients with documented stem fractures. Data collected included patient demographics (age, sex, BMI), implant details (stem size, head diameter), and the time from primary surgery to failure. Explanted stems underwent macroscopic evaluation, chemical analysis, and structural assessment using scanning electron microscopy (SEM). All fractured stems were the smallest available sizes (0 or 01) and were paired with XL or XXL femoral heads. The average time from implantation to revision surgery was 88 months (range: 70–102 months). The average BMI was 27.9 kg/m² (range: 20.3–31.1 kg/m²). Macroscopic examination revealed fatigue fractures covering more than 80% of the load-bearing cross-section. Chemical analysis showed that the implants consisted of two distinct materials: the head (AISI 316L steel) and the stem (06Cr18Ni11Nb alloy, AISI 347). Alloy analysis confirmed that the chemical composition largely met standard requirements, except for elevated manganese (Mn) levels and suboptimal niobium (Nb) content, likely due to processing issues. Fractography demonstrated crack initiation in high-stress areas (thread region), with signs of corrosion fatigue and secondary cracking contributing to the failure. Fatigue failure of cemented stems is a rare event. Identified risk factors include small-sized stems combined with larger femoral heads, which increase postoperative offset and biomechanical stress. Material issues, including substandard alloy composition and processing defects, combined with electrochemical interactions between different materials, further predispose these stems to failure.
Zitieren
APA
Melišík, M., Palček, P., Nečas, L., Žofčák, M., Al-Khouri, M., & Hrubina, M. (2026). Fatigue fracture of the Logica cemented stem – Clinical and mechanical analysis. Lékař a technika - Clinician and Technology, 56, 5-11. https://doi.org/10.14311/ctj.2026.56.01
Vancouver
Melišík M, Palček P, Nečas L, Žofčák M, Al-Khouri M, Hrubina M. Fatigue fracture of the Logica cemented stem – Clinical and mechanical analysis. Lékař a technika - Clinician and Technology. 2026;56:5-11. doi:10.14311/ctj.2026.56.01
BibTeX
@article{Melik2026,
author = {Melišík, Marián and Palček, Peter and Nečas, Libor and Žofčák, Martin and Al-Khouri, Michal and Hrubina, Maroš},
title = {Fatigue fracture of the Logica cemented stem – Clinical and mechanical analysis},
journal = {Lékař a technika - Clinician and Technology},
year = {2026},
volume = {56},
pages = {5--11},
doi = {10.14311/ctj.2026.56.01}
}
EUVIMED