FREQUENCY AND DURATION OF OXIMETER DROP-OUTS IN THE NICU: AN OBSERVATIONAL STUDY

Thomas Edward Bachman, Karel Roubik

Lékař a technika - Clinician and Technology · 2020

DOI: 10.14311/ctj.2020.1.02 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lékař a technika - Clinician and Technology, 2020. Verfasst von Thomas Edward Bachman und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oximeters used for continuous monitoring experience periods with no signal. This SpO2drop-out is widely acknowledged and its causes generally understood. This is a prospectively designed analysis of an existing database with the aim of characterizing drop-outs as experienced in the neonatal ICU. The data reflects 116 days of monitoring in seven tertiary care neonatal ICUs in 6 countries. From the evaluation of 1,396 drop-outs we found that typically the time was minimal with missing SpO2 data, and the episodes were short (median 2.79 minutes per day IQR 0.17-76, median 22 seconds IQR: 15-37, respectively). During during about half of the days there were no prolonged dropouts (1 minute or longer), even so half of the total time spent with no SpO2data were in prolonged episodes (median length 110 seconds IQR 85-150). The predominate factor associated with excessive drop-out time was the number of prolonged episodes rather than their duration. We concluded that the impact of drop-outs during manual control of inspired oxygen primarily impact alarm fatigue, but that during automatic FiO2control they could have an important impact. The relative effectiveness of the fall-back strategies of these automatic control systems ought to be evaluated.

Zitieren

APA

Bachman, T. E., & Roubik, K. (2020). FREQUENCY AND DURATION OF OXIMETER DROP-OUTS IN THE NICU: AN OBSERVATIONAL STUDY. Lékař a technika - Clinician and Technology. https://doi.org/10.14311/ctj.2020.1.02

Vancouver

Bachman TE, Roubik K. FREQUENCY AND DURATION OF OXIMETER DROP-OUTS IN THE NICU: AN OBSERVATIONAL STUDY. Lékař a technika - Clinician and Technology. 2020. doi:10.14311/ctj.2020.1.02

BibTeX
@article{Bachman2020,
  author = {Bachman, Thomas Edward and Roubik, Karel},
  title = {FREQUENCY AND DURATION OF OXIMETER DROP-OUTS IN THE NICU: AN OBSERVATIONAL STUDY},
  journal = {Lékař a technika - Clinician and Technology},
  year = {2020},
  doi = {10.14311/ctj.2020.1.02}
}
Kostenlos starten →