EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

THE TIME DELAY OF AIR/OXYGEN MIXTURE DELIVERY AFTER THE CHANGE OF SET FIO2: AN IMPROVEMENT OF A NEONATAL MATHEMATICAL MODEL

Leoš Tejkl, Jakub Ráfl, Petr Kudrna

Lékař a technika - Clinician and Technology · 2020

DOI: 10.14311/ctj.2019.3.01 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Lékař a technika - Clinician and Technology, 2020. Verfasst von Leoš Tejkl und 2 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oxygen therapy is an essential treatment of premature infants suffering from hypoxemia. Normoxemia is maintained by an adjustment of the fraction of oxygen (FiO2) in the inhaled gas mixture that is set manually or automatically based on peripheral oxygen saturation (SpO2). Automatic closed-loop systems could be more successful in controlling SpO2 than traditional manual approaches. Computer models of neonatal oxygen transport have been developed as a tool for design, validation, and comparison of the automatic control algorithms. The aim of this study was to investigate and implement the time delay of oxygen delivery after a change of set FiO2 during noninvasive ventilation support to enhance an available mathematical model of neonatal oxygen transport. The time delay of oxygen delivery after the change of FiO2 during the noninvasive nasal Continuous Positive Airway Pressure (nCPAP) ventilation support and during the High Flow High Humidity Nasal Cannula (HFHHNC) ventilation support was experimentally measured using an electromechanical gas blender and a physical model of neonatal lungs. Results show the overall time delay of the change in the oxygen fraction can be divided into the baseline of delay, with a typical time delay 5.5 s for nCPAP and 6.5 s for HFHHNC s, and an exponential rising phase with a time constant about 2–3 s. A delay subsystem was implemented into the mathematical model for a more realistic performance when simulating closed-loop control of oxygenation.

Zitieren

APA

Tejkl, L., Ráfl, J., & Kudrna, P. (2020). THE TIME DELAY OF AIR/OXYGEN MIXTURE DELIVERY AFTER THE CHANGE OF SET FIO2: AN IMPROVEMENT OF A NEONATAL MATHEMATICAL MODEL. Lékař a technika - Clinician and Technology. https://doi.org/10.14311/ctj.2019.3.01

Vancouver

Tejkl L, Ráfl J, Kudrna P. THE TIME DELAY OF AIR/OXYGEN MIXTURE DELIVERY AFTER THE CHANGE OF SET FIO2: AN IMPROVEMENT OF A NEONATAL MATHEMATICAL MODEL. Lékař a technika - Clinician and Technology. 2020. doi:10.14311/ctj.2019.3.01

BibTeX
@article{Tejkl2020,
  author = {Tejkl, Leoš and Ráfl, Jakub and Kudrna, Petr},
  title = {THE TIME DELAY OF AIR/OXYGEN MIXTURE DELIVERY AFTER THE CHANGE OF SET FIO2: AN IMPROVEMENT OF A NEONATAL MATHEMATICAL MODEL},
  journal = {Lékař a technika - Clinician and Technology},
  year = {2020},
  doi = {10.14311/ctj.2019.3.01}
}
Kostenlos starten →