EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Negative Moment Zone in UHPC-Strengthened Simply-Supported-to-Continuous Concrete Box Beams: Cracking Resistance Analysis

Junming Huang, Kexin Zhang, Jiaqi Qiu

Stavební obzor - Civil Engineering Journal · 30.04.2026 · 35 (1) · 17-33

DOI: 10.14311/cej.2026.01.0002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stavební obzor - Civil Engineering Journal, online erschienen am 30.04.2026. Verfasst von Junming Huang und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, to investigate the cracking resistance of UHPC-strengthened simply-supported-to-continuous concrete box beams in the negative moment zone, a total of nine specimens were designed: one reinforced concrete box beam (comparison beam), seven UHPC-RC composite box beams (reinforced beams), and one prestressed concrete box beam (prestressed beam). The research focuses on evaluating the influence of key parameters—including reinforcement ratio, UHPC casting length in the negative moment zone, UHPC thickness, and the joint configuration between UHPC and ordinary concrete—on the cracking resistance of these beams. The results demonstrate that, under the same reinforcement ratio, UHPC strengthening in the negative moment zone significantly enhances the cracking performance of the test beams, with the cracking load increasing by 46%. As the UHPC casting length increases, the maximum crack width at the vertical interface between the full normal concrete (NC) section and the UHPC-NC composite section decreases markedly. Additionally, increasing the UHPC thickness leads to a substantial reduction in the maximum crack width at both the UHPC-NC composite section and the intermediate diaphragm section. Received: 28.05.2025Received in revised form: 21.01.2026Accepted: 19.03.2026

Zitieren

APA

Huang, J., Zhang, K., & Qiu, J. (2026). Negative Moment Zone in UHPC-Strengthened Simply-Supported-to-Continuous Concrete Box Beams: Cracking Resistance Analysis. Stavební obzor - Civil Engineering Journal, 35(1), 17-33. https://doi.org/10.14311/cej.2026.01.0002

Vancouver

Huang J, Zhang K, Qiu J. Negative Moment Zone in UHPC-Strengthened Simply-Supported-to-Continuous Concrete Box Beams: Cracking Resistance Analysis. Stavební obzor - Civil Engineering Journal. 2026;35(1):17-33. doi:10.14311/cej.2026.01.0002

BibTeX
@article{Huang2026,
  author = {Huang, Junming and Zhang, Kexin and Qiu, Jiaqi},
  title = {Negative Moment Zone in UHPC-Strengthened Simply-Supported-to-Continuous Concrete Box Beams: Cracking Resistance Analysis},
  journal = {Stavební obzor - Civil Engineering Journal},
  year = {2026},
  volume = {35},
  number = {1},
  pages = {17--33},
  doi = {10.14311/cej.2026.01.0002}
}
Kostenlos starten →