EUVIMEDEUVIMED entdecken
VergleichsstudieQuerschnittstudieOpen Access · CC BY-NC-ND 4.0

Comparative Analysis of Gait Speed Measurement Protocols: Static Start Versus Dynamic Start in a Cross-Sectional Study Using Light Detection and Ranging

S Ji, H-W Jung, S Yoon, H Roh, M Kim, H Jung, R Jang, H Ha, J Y Baek, I-Y Jang, E Lee

The Journal of Frailty & Aging · 2024

DOI: 10.14283/jfa.2024.48 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of Frailty & Aging, 2024. Verfasst von S Ji und 10 weiteren Autor:innen. Beteiligte Einrichtung: Hee-Won Jung, MD, PhD, Division of Geriatrics, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88, Oly…. Hauptthemen laut MEDLINE: Walking Speed, Geriatric Assessment. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: There is currently no standardized protocol for the measurement of gait speed in older adults, particularly regarding the choice between static versus dynamic start. OBJECTIVES: This study aimed to assess the impact of removing the initial phase on gait speed measurement and compare the correlation of different measurement methods with other physical performance metrics. DESIGN: A cross-sectional study. SETTING: A geriatric clinic in a tertiary hospital in Seoul, Korea. PARTICIPANTS: Adults aged 65 years or older who underwent physical performance examinations during comprehensive geriatric assessments (n = 511). MEASUREMENTS: A one-dimensional light detection and ranging device was used to obtain real-time gait signal data and measure the participants' gait speed. Descriptive statistics were obtained for the acceleration phase. Various lengths of the initial phase were removed to determine the point at which gait speed plateaued. Correlations between four-meter gait speeds, with different initial phase lengths, and chair stand and balance test results were examined. RESULTS: The mean ± standard deviation of the acceleration phase (m) was 0.92 ± 0.51. The removal of various initial phase lengths showed that 2 m gait speed based on dynamic start (0.5 m) significantly differed from static start (0.7 m/s versus 1.05 m/s, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Walking SpeedGeriatric AssessmentHumansCross-Sectional StudiesAgedMaleFemaleAged, 80 and overRepublic of KoreaAccelerationPostural BalanceGait AnalysisGait

Stichwörter der Autor:innen

Gait speedacceleration phaselight detection and rangingphysical performance

Autor:innen und Institutionen

  • Hee-Won Jung, MD, PhD, Division of Geriatrics, Department of Internal Medicine, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Republic of Korea, Tel: +82-2-…

Zitieren

APA

Ji, S., Jung, H. W., Yoon, S., Roh, H., Kim, M., Jung, H., Jang, R., Ha, H., Baek, J. Y., Jang, I. Y., & Lee, E. (2024). Comparative Analysis of Gait Speed Measurement Protocols: Static Start Versus Dynamic Start in a Cross-Sectional Study Using Light Detection and Ranging. The Journal of Frailty & Aging. https://doi.org/10.14283/jfa.2024.48

Vancouver

Ji S, Jung HW, Yoon S, Roh H, Kim M, Jung H, et al. Comparative Analysis of Gait Speed Measurement Protocols: Static Start Versus Dynamic Start in a Cross-Sectional Study Using Light Detection and Ranging. The Journal of Frailty & Aging. 2024. doi:10.14283/jfa.2024.48

BibTeX
@article{Ji2024,
  author = {Ji, S and Jung, H-W and Yoon, S and Roh, H and Kim, M and Jung, H and Jang, R and Ha, H and Baek, J Y and Jang, I-Y and Lee, E},
  title = {Comparative Analysis of Gait Speed Measurement Protocols: Static Start Versus Dynamic Start in a Cross-Sectional Study Using Light Detection and Ranging},
  journal = {The Journal of Frailty & Aging},
  year = {2024},
  doi = {10.14283/jfa.2024.48}
}
Kostenlos starten →