EUVIMEDEUVIMED entdecken
KohortenstudieOpen Access · CC BY-NC 3.0

Magnetic Resonance Imaging-Based Radiomics for Quantitative Assessment of Cervical Disc Degeneration: A Dual-Cohort Study

Chaofeng Zhang, Yahao Li, Pengfei Yu, Zhijian Qi, Qinghua Wang, Daibin Li, Feifei Gao, Xiaobing Ren, Changhong Chen

Neurospine · 31.10.2026 · 23 (4) · 992-1004

DOI: 10.14245/ns.26520612.0306 ↗

Kurz gefasst

Kohortenstudie in der Zeitschrift Neurospine, erschienen am 31.10.2026. Verfasst von Chaofeng Zhang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Jiangyin Hospital Affiliated to Nanjing University of Chinese Medicine, Jiangyin, China. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 3.0). Gefördert von: Research Project of Jiangyin Society of Traditional Chinese Medicine, Jiangyin Young and Middle-aged Health Excellent Talents Project, 2024 Jiangyin Science and Technology Innovation Special Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Cervical disc degeneration (CDD) is commonly evaluated using magnetic resonance imaging (MRI)-based Pfirrmann grading, but this visual semiquantitative system remains observer-dependent and may not fully capture intradiscal heterogeneity. This study aimed to develop and externally validate a low-dimensional, interpretable MRI-based radiomics model for identifying Pfirrmann-defined moderate-to-severe CDD using routine midsagittal T2-weighted imaging.

Methods

This retrospective dual-cohort study included 374 patients with 1,870 discs in the internal cohort and 66 patients with 330 clinically graded discs in the external cohort. Quantitative features reflecting signal distribution, texture-based spatial gray-level relationships, and morphology were extracted from manually delineated disc regions of interest on midsagittal T2-weighted images. A multivariable logistic regression model was constructed, and internal validation was performed using patient-level 5-fold cross-validation. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, specificity, and patient-level bootstrap resampling. Calibration was assessed using calibration curves and the Hosmer-Lemeshow test, and imaging-based net benefit was evaluated using decision curve analysis (DCA).

Results

Most selected features showed good reproducibility, whereas 2-dimensional (2D) sphericity was less reproducible. In patient-level internal cross-validation, the combined model achieved the highest AUC (0.821; 95% CI, 0.797–0.846), exceeding that of the mean-intensity baseline model (0.677; 95% CI, 0.641–0.713; patient-level bootstrap p

Schlagwörter

Stichwörter der Autor:innen

Cervical disc degenerationMagnetic resonance imagingQuantitative imaging biomarkersRadiomicsT2-weighted imaging

Autor:innen und Institutionen

  • Department of Orthopaedics, Jiangyin Hospital Affiliated to Nanjing University of Chinese Medicine, Jiangyin, China.
  • Department of Orthopaedics, Suzhou TCM Hospital Affiliated to Nanjing University of Chinese Medicine, Suzhou, China.
  • Department of Orthopaedics, Jiangyin Hospital Affiliated to Nanjing University of Chinese Medicine, Jiangyin, China. changhongchen0917@163.com.

Förderung

  • Research Project of Jiangyin Society of Traditional Chinese Medicine
  • Jiangyin Young and Middle-aged Health Excellent Talents Project
  • 2024 Jiangyin Science and Technology Innovation Special Project
  • Special Project for Research and Development of Off-campus Teaching Base of Jiangsu Vocational College of Medicine
  • Jiangyin Hospital of Traditional Chinese Medicine Institutional Research Project

Zitieren

APA

Zhang, C., Li, Y., Yu, P., Qi, Z., Wang, Q., Li, D., Gao, F., Ren, X., & Chen, C. (2026). Magnetic Resonance Imaging-Based Radiomics for Quantitative Assessment of Cervical Disc Degeneration: A Dual-Cohort Study. Neurospine, 23(4), 992-1004. https://doi.org/10.14245/ns.26520612.0306

Vancouver

Zhang C, Li Y, Yu P, Qi Z, Wang Q, Li D, et al. Magnetic Resonance Imaging-Based Radiomics for Quantitative Assessment of Cervical Disc Degeneration: A Dual-Cohort Study. Neurospine. 2026;23(4):992-1004. doi:10.14245/ns.26520612.0306

BibTeX
@article{Zhang2026,
  author = {Zhang, Chaofeng and Li, Yahao and Yu, Pengfei and Qi, Zhijian and Wang, Qinghua and Li, Daibin and Gao, Feifei and Ren, Xiaobing and Chen, Changhong},
  title = {Magnetic Resonance Imaging-Based Radiomics for Quantitative Assessment of Cervical Disc Degeneration: A Dual-Cohort Study},
  journal = {Neurospine},
  year = {2026},
  volume = {23},
  number = {4},
  pages = {992--1004},
  doi = {10.14245/ns.26520612.0306}
}
Kostenlos starten →