Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion
Neurospine · 30.09.2024 · 21 (3) · 973-983
DOI: 10.14245/ns.2448244.122 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neurospine, erschienen am 30.09.2024. Verfasst von Ki-Han You und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
Biportal endoscopic transforaminal lumbar interbody fusion (BE-TLIF) is an emerging, minimally invasive technique performed under biportal endoscopic guidance. However, concerns regarding cage subsidence and sufficient fusion during BE-TLIF necessitate careful selection of an appropriate interbody cage to improve surgical outcomes. This study compared the fusion rate, subsidence, and other radiographic parameters according to the material and size of the cages used in BE-TLIF.
Methods
In this retrospective cohort study, patients who underwent single-segment BE-TLIF between April 2019 and February 2023 were divided into 3 groups: group A, regular-sized three-dimensionally (3D)-printed titanium cages; group B, regular-sized polyetheretherketone cages; and group C, large-sized 3D-printed titanium cages. Radiographic parameters, including lumbar lordosis, segmental lordosis, anterior and posterior disc heights, disc angle, and foraminal height, were measured before and after surgery. The fusion rate and severity of cage subsidence were compared between the groups.
Results
No significant differences were noted in the demographic data or radiographic parameters between the groups. The fusion rate on 1-year postoperative computed tomography was comparable between the groups. The cage subsidence rate was significantly lower in group C than in group A (41.9% vs. 16.7%, p=0.044). The severity of cage subsidence was significantly lower in group C (0.93±0.83) than in groups A (2.20±1.84, p=0.004) and B (1.79±1.47, p=0.048).
Conclusion
Cage materials did not affect the 1-year postoperative outcomes of BE-TLIF; however, subsidence was markedly reduced in large cages. Larger cages may provide more stable postoperative segments.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea.
- Department of Orthopaedic Surgery, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Department of Orthopedic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea.
- Department of Orthopedic Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seoul, Korea.
Zitieren
APA
You, K. H., Cho, S. K., Hwang, J. Y., Cha, S. H., Kang, M. S., Park, S. M., & Park, H. J. (2024). Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion. Neurospine, 21(3), 973-983. https://doi.org/10.14245/ns.2448244.122
Vancouver
You KH, Cho SK, Hwang JY, Cha SH, Kang MS, Park SM, et al. Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion. Neurospine. 2024;21(3):973-983. doi:10.14245/ns.2448244.122
BibTeX
@article{You2024,
author = {You, Ki-Han and Cho, Samuel K and Hwang, Jae-Yeun and Cha, Sun-Ho and Kang, Min-Seok and Park, Sang-Min and Park, Hyun-Jin},
title = {Effect of Cage Material and Size on Fusion Rate and Subsidence Following Biportal Endoscopic Transforaminal Lumbar Interbody Fusion},
journal = {Neurospine},
year = {2024},
volume = {21},
number = {3},
pages = {973--983},
doi = {10.14245/ns.2448244.122}
}
EUVIMED