Groundwater hardness characterization and selection of softening technology for development of a centralized treatment plant: A case study in Haramaya University, Ethiopia
PLOS Water · 02.06.2026 · 5 (6) · e0000454
DOI: 10.1371/journal.pwat.0000454 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS Water, online erschienen am 02.06.2026. Verfasst von Nagara Wakgari Futasa und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Groundwater hardness characterization is very important for suitable softening technology selection and development. Haramaya University (HU) is one of the Ethiopian public University that relies on groundwater for domestic and academic purposes. Lime scaling and pipe clogging is the main challenges of the HU’s water supply system. This study aimed to characterize groundwater hardness and identify an appropriate centralized softening technology. Samples from eight boreholes (BHs) were analyzed to identify hardness causing parameters, hardness type, and scaling and corrosion potential. Softening technologies were evaluated based on treatment potential and feasibility factor criteria, and the Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) was applied to select the ideal softening technology. Result showed that concentrations of Ca 2+ , Mg 2+ , HCO 3 , Cl - , and SO 4 2- ranged from 75 to 107 mg/L, 41–60 mg/L, 275–360 mg/L CaCO 3 , 7.5 to 17.5 mg/L, and 2 to 4.6 mg/L, respectively, resulting in very hard groundwater (>300 mg/L CaCO 3 ) at HU. The Langelier Saturation Index (LSI), Aggressive Index (AI), and Larson–Skold Index (LS) indicated scaling potential in all water samples. The Ryznar Stability Index (RSI) showed slight corrosion potential in BH1 and BH2, neutral indications in BH3, BH4, BH5, and BH6, and scaling potential in BH7 and BH8. Based on the analysis of softening technology alternatives, Reverse Osmosis (RO) was selected as the suitable technology for developing a centralized softening technology at HU. This finding is very important for HU and others facing similar challenges.
Zitieren
APA
Futasa, N. W., Ante, A. A., & Adugna, D. B. (2026). Groundwater hardness characterization and selection of softening technology for development of a centralized treatment plant: A case study in Haramaya University, Ethiopia. PLOS Water, 5(6), e0000454. https://doi.org/10.1371/journal.pwat.0000454
Vancouver
Futasa NW, Ante AA, Adugna DB. Groundwater hardness characterization and selection of softening technology for development of a centralized treatment plant: A case study in Haramaya University, Ethiopia. PLOS Water. 2026;5(6):e0000454. doi:10.1371/journal.pwat.0000454
BibTeX
@article{Futasa2026,
author = {Futasa, Nagara Wakgari and Ante, Abera Atumo and Adugna, Deressa Boja},
title = {Groundwater hardness characterization and selection of softening technology for development of a centralized treatment plant: A case study in Haramaya University, Ethiopia},
journal = {PLOS Water},
year = {2026},
volume = {5},
number = {6},
pages = {e0000454},
doi = {10.1371/journal.pwat.0000454}
}
EUVIMED