EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Long-term trial of a community-scale decentralized point-of-use drinking water treatment system

Gillian E. Clayton, Robin M. S. Thorn, Bethany G. Fox, Darren M. Reynolds

PLOS Water · 04.04.2024 · 3 (4) · e0000187

DOI: 10.1371/journal.pwat.0000187 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS Water, online erschienen am 04.04.2024. Verfasst von Gillian E. Clayton und 3 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Environment Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Two billion people lack access to safely managed drinking water services, many of these are in low/middle income countries where centralised systems are impractical. Decentralised point-of-use drinking water treatment systems offer alternative solutions in remote or resource constrained settings. The main aim of this study was to assess the long-term (3 year) operation and performance of a point-of-use drinking water treatment system (POU-DWTS). A biologically contaminated urban drainage pond was used as a water source and the quality of the produced drinking water was assessed over two independent trials. The decentralised POU-DWTS combined ultrafiltration membranes with disinfection from electrochemically generated hypochlorous acid (HOCl). The operational parameters, such as flow rate, free available chlorine and transmembrane pressure, were monitored in real-time and recorded via a remote monitoring system. Water quality from the source and treated water was assessed over two trial periods within the 3-year operational trial: an 11-week period at the start and a 22-week trial at the end. All water samples were assessed for a range of basic, chemical, microbiological and metal water quality parameters. The results demonstrate that the decentralised POU-DWTS is capable of continuously producing high quality drinking water when HOCl is continuously used to dose water prior to entering the ultrafiltration [UF] membranes. Over the 3-year operational study, the continuous dosing of HOCl pre-UF membranes resulted in stable permeability, indicating no occurrences of irreversible biofouling within the UF membranes and that good membrane ‘health’ was maintained throughout. As such, there was no need to replace the UF membranes nor undertake acid/alkaline chemical cleans at any point throughput the three-year study. The POU-DWTS continuously produced high quality drinking water, resulting in 6453 m 3 of drinking water produced over the trial period, that met international water quality standards, at a community scale within the location studied.

Förderung

  • Natural Environment Research Council

Zitieren

APA

Clayton, G. E., Thorn, R. M. S., Fox, B. G., & Reynolds, D. M. (2024). Long-term trial of a community-scale decentralized point-of-use drinking water treatment system. PLOS Water, 3(4), e0000187. https://doi.org/10.1371/journal.pwat.0000187

Vancouver

Clayton GE, Thorn RMS, Fox BG, Reynolds DM. Long-term trial of a community-scale decentralized point-of-use drinking water treatment system. PLOS Water. 2024;3(4):e0000187. doi:10.1371/journal.pwat.0000187

BibTeX
@article{Clayton2024,
  author = {Clayton, Gillian E. and Thorn, Robin M. S. and Fox, Bethany G. and Reynolds, Darren M.},
  title = {Long-term trial of a community-scale decentralized point-of-use drinking water treatment system},
  journal = {PLOS Water},
  year = {2024},
  volume = {3},
  number = {4},
  pages = {e0000187},
  doi = {10.1371/journal.pwat.0000187}
}
Kostenlos starten →