Intelligent compensation method for measurement errors in optical fiber current sensor caused by temperature variation based on the Levy-Weighted-QPSO-NN algorithm
PLOS One · 06.07.2026 · 21 (7) · e0363631
DOI: 10.1371/journal.pone.0363631 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 06.07.2026. Verfasst von Lin Cheng und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Grid Shaanxi Electric Power Co., Ltd. Electric Power Research Institute, Xi'an, China. Hauptthemen laut MEDLINE: Temperature, Algorithms, Fiber Optic Technology, Neural Networks, Computer. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Innovation Project, National Natural Science Foundation of China.
Abstract (Originalsprache)
Temperature variations significantly degrade the measurement accuracy of fiber optic current sensors (FOCS) in critical power systems applications such as high-voltage transmission and renewable energy integration. To address this, we propose an intelligent error compensation method based on an improved Quantum-behaved Particle Swarm Optimization-Neural Network (Levy-Weighted-QPSO-NN) algorithm. The approach leverages easily measurable state parameters—sensing ring temperature, received optical power, half-wave voltage, SLD temperature, and SLD current—as inputs to predict temperature-induced current ratio difference. Experimental validation involved three sensing rings subjected to temperature cycling (−45 °C to 70 °C), emulating harsh substation environments. The Levy-Weighted-QPSO-NN model achieved 91.11% average prediction accuracy for ratio difference with a correlation coefficient (R²) of 0.9223, outperforming QPSO-NN (85.69%) and Weighted-QPSO-NN (88.31%). Key metrics (MAE: 0.0784; RMSE: 0.0819) confirmed superior stability and accuracy. Robustness testing demonstrated consistent performance across varying population sizes (25–70) and iterations (90–150). Using predicted ratio differences for real-time compensation reduced measurement errors from 0.82% to 0.13%, meeting IEC 61869–6/8 and GB/T standards for Class 0.2S accuracy. This method eliminates reliance on complex hardware modifications, offering a generic, algorithm-driven solution for temperature-dependent FOCS errors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- State Grid Shaanxi Electric Power Co., Ltd. Electric Power Research Institute, Xi'an, China.
- State Grid Shaanxi Electric Power Co., Ltd, Xi'an, China.
- State Grid Shaanxi Electric Power Co., Ltd. Ultra-high Voltage Company, Xi'an, China.
ORCID-Profile: Lin Cheng
Förderung
- Scientific and Technological Innovation Project
- National Natural Science Foundation of China
Zitieren
APA
Cheng, L., Luo, J., Si, W., Han, Y., Zuo, K., Sun, H., Niu, B., & Ren, S. (2026). Intelligent compensation method for measurement errors in optical fiber current sensor caused by temperature variation based on the Levy-Weighted-QPSO-NN algorithm. PLOS One, 21(7), e0363631. https://doi.org/10.1371/journal.pone.0363631
Vancouver
Cheng L, Luo J, Si W, Han Y, Zuo K, Sun H, et al. Intelligent compensation method for measurement errors in optical fiber current sensor caused by temperature variation based on the Levy-Weighted-QPSO-NN algorithm. PLOS One. 2026;21(7):e0363631. doi:10.1371/journal.pone.0363631
BibTeX
@article{Cheng2026,
author = {Cheng, Lin and Luo, Jianyong and Si, Weibin and Han, Yanhua and Zuo, Kun and Sun, Haitao and Niu, Bo and Ren, Shuangzan},
title = {Intelligent compensation method for measurement errors in optical fiber current sensor caused by temperature variation based on the Levy-Weighted-QPSO-NN algorithm},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {7},
pages = {e0363631},
doi = {10.1371/journal.pone.0363631}
}
EUVIMED