Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia
PLOS One · 06.11.2026 · 21 (11) · e0362073
DOI: 10.1371/journal.pone.0362073 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 06.11.2026. Verfasst von Karolina Tlałka und 9 weiteren Autor:innen. Beteiligte Einrichtung: Division of Clinical Medicine, School of Medicine and Population Health, University of Sheffield, Sheffield, United Kingdom. Hauptthemen laut MEDLINE: Baroreflex, Hypovolemia, Models, Cardiovascular. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education, Poland, Horizon 2020, Academic Computer Centre Cyfronet, AGH University of Science and Technology.
Abstract (Originalsprache)
Calibration of cardiovascular models is essential to their clinical utility. We provide a full description of the calibration of a non-linear, dynamic model using global optimisation methods. Specifically, we consider an experimental cohort response in a closed-loop, baro-regulated cardiovascular model, in the setting of induced central hypovolemia.We propose a framework for simplifying calibration of dynamic, regulated models. We perform global sensitivity analysis and orthogonality analysis of a 58-parameter non-linear cardiovascular model including the baroreflex, to select an optimal subset of parameters for model calibration. We fit the model to relative Lower Body Negative Pressure data, using global optimisation (Differential Evolution method), searching a reduced input parameter space. Global sensitivity analysis and orthogonality analysis revealed multiple higher-order interactions within the model, as well as areas of similar influence of input parameters, on the components of the objective function. The model was fitted using only baroreflex parameters. Relative errors in the estimation of heart rate, mean arterial pressure, and stroke volume were reduced from −15.03%, 1.60% and 42.06% before calibration to 0.42%, −1.37% and 0.61% after the fitting, respectively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Clinical Medicine, School of Medicine and Population Health, University of Sheffield, Sheffield, United Kingdom.
- Sano Centre for Computational Medicine, Kraków, Poland.
- Astellas Pharma Europe Ltd, Addlestone, England.
- Insigneo Institute for Healthcare Technology, Sheffield, United Kingdom.
- School of Computer Science, University of Sheffield, Sheffield, United Kingdom.
- NIHR Sheffield Biomedical Research Centre, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, United Kingdom.
ORCID-Profile: Karolina Tlałka, Harry Saxton, Xu Xu, Jonny Hisdal
Förderung
- Ministry of Science and Higher Education, Poland
- Horizon 2020
- Academic Computer Centre Cyfronet, AGH University of Science and Technology
Zitieren
APA
Tlałka, K., Saxton, H., Halliday, I., Xu, X., Narracott, A., Taylor, D. J., Høiseth, L. Ø., Hisdal, J., Hose, D. R., & Malawski, M. (2026). Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia. PLOS One, 21(11), e0362073. https://doi.org/10.1371/journal.pone.0362073
Vancouver
Tlałka K, Saxton H, Halliday I, Xu X, Narracott A, Taylor DJ, et al. Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia. PLOS One. 2026;21(11):e0362073. doi:10.1371/journal.pone.0362073
BibTeX
@article{Tlaka2026,
author = {Tlałka, Karolina and Saxton, Harry and Halliday, Ian and Xu, Xu and Narracott, Andrew and Taylor, Daniel James and Høiseth, Lars Øivind and Hisdal, Jonny and Hose, David Rodney and Malawski, Maciej},
title = {Calibration of a fully closed-loop lumped-parameter cardiovascular model with baroreflex in response to induced central hypovolemia},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {11},
pages = {e0362073},
doi = {10.1371/journal.pone.0362073}
}
EUVIMED