Lens dislocation, OCTA, and archived FBN1 reports: An exploratory study
PLOS One · 2026
DOI: 10.1371/journal.pone.0361193 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Muhammer Özgür Çevik und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Genetics, Adiyaman University Faculty of Medicine, Adiyaman, Türkiye. Hauptthemen laut MEDLINE: Fibrillin-1, Tomography, Optical Coherence, Ectopia Lentis, Lens Subluxation. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Lens dislocation (ectopia lentis) is a recognized anterior-segment manifestation of fibrillinopathy. This exploratory phenotype-first study compared macular optical coherence tomography angiography (OCTA) parameters between participants with and without documented lens dislocation and descriptively reviewed available archived clinical FBN1 reports.
Methods
This retrospective, availability-based study included 16 participants classified by verified current or historical lens-dislocation status. Participant-level superficial capillary plexus (SCP) vessel density was calculated by averaging valid bilateral measurements or using the single valid eye. Five OCTA endpoints were compared using two-sided Mann–Whitney U tests; Benjamini–Hochberg q values were used as a multiplicity sensitivity analysis. Seven archived clinical FBN1 reports from lens-dislocation-positive (LD+) participants were summarized without variant reclassification. No genotype–OCTA association was assessed.
Results
The cohort comprised 7 LD+ and 9 lens-dislocation-negative (LD−) participants; 15 participants (6 LD+ and 9 LD−) contributed quantitative OCTA data. Foveal SCP vessel density was lower in LD+ participants (median [IQR], 19.38% [18.68–20.04] vs 30.20% [29.20–31.85]; p = 0.036), but the finding was not retained after multiplicity sensitivity analysis (q = 0.180). Whole-image, parafoveal, and perifoveal vessel-density comparisons were not significant (p = 0.328, 0.272, and 0.238; q = 0.410 each), and OD-only foveal avascular zone area did not differ (n = 14; p = 0.606; q = 0.606). Six of seven archived reports documented an FBN1 variant; one was negative within its assay scope.
Conclusions
The unadjusted foveal signal was not robust to multiplicity analysis, and other OCTA endpoints did not differ significantly. Marked between-group differences in spherical equivalent and axial length, the small sample, and heterogeneous routine-care genetic reports limit interpretation. These findings are hypothesis-generating and do not establish OCTA as a diagnostic or prognostic test or demonstrate an individual-level genotype–OCTA association.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Medical Genetics, Adiyaman University Faculty of Medicine, Adiyaman, Türkiye.
- Department of Ophthalmology, Beyoglu Eye Training and Research Hospital, Istanbul, Türkiye.
- Department of Ophthalmology, Bursa Yüksek İhtisas Training and Research Hospital, Bursa, Türkiye.
ORCID-Profile: Muhammer Özgür Çevik
Zitieren
APA
Çevik, M. Ö., Simsek, M., Cevik, S. G., & Perente, I. (2026). Lens dislocation, OCTA, and archived FBN1 reports: An exploratory study. PLOS One. https://doi.org/10.1371/journal.pone.0361193
Vancouver
Çevik MÖ, Simsek M, Cevik SG, Perente I. Lens dislocation, OCTA, and archived FBN1 reports: An exploratory study. PLOS One. 2026. doi:10.1371/journal.pone.0361193
BibTeX
@article{evik2026,
author = {Çevik, Muhammer Özgür and Simsek, Metehan and Cevik, Sadik Gorkem and Perente, Irfan},
title = {Lens dislocation, OCTA, and archived FBN1 reports: An exploratory study},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0361193}
}
EUVIMED