Robust ghost marker rejection in marker-based optical tracking using contour-derived monocular depth priors
PLOS One · 13.11.2026 · 21 (11) · e0361058
DOI: 10.1371/journal.pone.0361058 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 13.11.2026. Verfasst von Enzan Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou, China. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 国家专项:放射介入手术机器人整机与核心零部件国产化攻关及应用.
Abstract (Originalsprache)
Marker-based stereo optical tracking can be disrupted by reflective interference and ambiguous correspondences when marker projections lie near the same epipolar line. We developed a tracking method that combines contour-based marker detection and constrained ellipse fitting with contour-derived monocular depth priors, uncertainty-normalized stereo matching, and adaptive region-of-interest (ROI) processing. In the reprojection-consistency evaluation, the proposed localization method achieved mean errors of 0.0532 and 0.0552 pixels in the left and right cameras, respectively, compared with 0.0827 and 0.0843 pixels for grayscale-centroid localization. In a separate inter-marker distance experiment involving 150 stereo observations, its mean absolute error was 0.0458 mm, compared with 0.0515 mm for OpenCV fitEllipse and 0.0551 mm for the grayscale-centroid method. In 50 stereo frames with deliberately induced ghost-marker ambiguity, the proposed matching method met the predefined frame-level correctness criterion in all 50 frames, compared with 20 frames for epipolar-only matching and 37 frames for MSRC. All expected markers were detected without false positives in the 100 images acquired for the paired illumination experiment. With 1–15 markers, adaptive ROI processing maintained a mean algorithmic processing time below 20 ms per stereo frame pair; at 15 markers, the mean was 16.52 ms and the 95th percentile was 21.20 ms. These results demonstrate improved measurement and matching performance under the tested laboratory conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Mechanical Engineering, Hangzhou Dianzi University, Hangzhou, China.
- Wenzhou Institute of Hangzhou Dianzi University, Wenzhou, China.
- Mstar Technologies, Inc., Hangzhou, China.
- Department of Geriatrics, the First Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, China.
- Chongqing Railway Transport Technician College, Shapingba, Chongqing, China.
- Shanghai Starriver Bilingual School, Shanghai, China.
ORCID-Profile: Enzan Chen, Ange Wang
Förderung
- 国家专项:放射介入手术机器人整机与核心零部件国产化攻关及应用
Zitieren
APA
Chen, E., Zhou, R., Wang, A., Chien, C. J. T., Zhu, J., & Ruan, Z. (2026). Robust ghost marker rejection in marker-based optical tracking using contour-derived monocular depth priors. PLOS One, 21(11), e0361058. https://doi.org/10.1371/journal.pone.0361058
Vancouver
Chen E, Zhou R, Wang A, Chien CJT, Zhu J, Ruan Z. Robust ghost marker rejection in marker-based optical tracking using contour-derived monocular depth priors. PLOS One. 2026;21(11):e0361058. doi:10.1371/journal.pone.0361058
BibTeX
@article{Chen2026,
author = {Chen, Enzan and Zhou, Rougang and Wang, Ange and Chien, Chou Jay Tsai and Zhu, Junjie and Ruan, Zhenchao},
title = {Robust ghost marker rejection in marker-based optical tracking using contour-derived monocular depth priors},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {11},
pages = {e0361058},
doi = {10.1371/journal.pone.0361058}
}
EUVIMED