EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study

Ai Cao My Bui, Quynh Tran Nhat Nguyen, Anh Ngoc Minh Bui, Minh Vu Phuc Ha iD, Nhan Phu Nguyen, Thy Ha Anh Nguyen, Nhan Quoc Dang, Phuong Minh Tran, Tu Vu Kha, Nhu Dong Phuong Nguyen, Liem Diep Bao Le, Huy Hoai Tran und 2 weitere

PLOS One · 02.11.2026 · 21 (11) · e0360957

DOI: 10.1371/journal.pone.0360957 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS One, online erschienen am 02.11.2026. Verfasst von Ai Cao My Bui und 13 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam. Hauptthemen laut MEDLINE: Blood Pressure Monitoring, Ambulatory, Hypertension, Blood Pressure, Blood Pressure Determination. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ambulatory blood pressure monitoring (ABPM) is the reference standard for diagnosing hypertension (HTN), but its use in routine practice remains limited because of cost, availability, and patient burden. Automated office blood pressure (AOBP) has been proposed as a practical alternative, although its performance relative to ABPM remains uncertain.

Objectives

To evaluate the agreement and diagnostic performance of 30-minute AOBP compared with 24-hour ABPM and to identify optimal cut-off values for detecting ambulatory hypertension.

Methods

In this prospective cohort study, 79 adults undergoing ABPM also underwent 30-minute AOBP measurement with automated readings every 5 minutes. The mean of the final six measurements was analyzed. Agreement was assessed using paired comparisons and Bland–Altman analysis. Diagnostic performance using receiver operating characteristic (ROC) analysis and agreement statistics.

Results

Thirty-minute AOBP values were consistently higher than ABPM measurements. Mean differences were +6.59/ + 7.27 mmHg for systolic/diastolic BP versus 24-hour ABPM and +3.73/ + 5.16 mmHg versus daytime ABPM (all p < 0.001). Bland–Altman analysis showed acceptable group-level agreement but wide limits of agreement. Sensitivity ranged from 84% to 96% and specificity from 28% to 79%. ROC analysis demonstrated good discrimination (AUC 0.77–0.87). The highest agreement with overall ABPM occurred at a cut-off of ≥140/84 mmHg (κ = 0.624).

Conclusions

Thirty-minute AOBP showed good discrimination for elevated ambulatory blood pressure but systematically overestimated BP relative to ABPM. It may serve as a practical screening tool, although normal AOBP values cannot reliably exclude ambulatory HTN and confirmation with 24-hour ABPM remains necessary. Central Illustration Diagnostic Performance of 30-Minute Automated Office Blood Pressure Compared With 24-Hour Ambulatory Monitoring

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure Monitoring, AmbulatoryHypertensionBlood PressureBlood Pressure DeterminationHumansProspective StudiesFemaleMaleMiddle AgedROC CurveAdultAgedAutomation

Autor:innen und Institutionen

  • School of Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
  • Department of Interventional Cardiology, University Medical Center Ho Chi Minh City, Ho Chi Minh City, Vietnam.
  • Faculty of Public Health, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
  • Department of Cardiology, University Medical Center Ho Chi Minh City, Ho Chi Minh City, Vietnam.

ORCID-Profile: Minh Vu Phuc Ha, Dung The Bui, Nghia Phu Nguyen

Zitieren

APA

Bui, A. C. M., Nguyen, Q. T. N., Bui, A. N. M., Ha, M. V. P., Nguyen, N. P., Nguyen, T. H. A., Dang, N. Q., Tran, P. M., Kha, T. V., Nguyen, N. D. P., Le, L. D. B., Tran, H. H., Bui, D. T., & Nguyen, N. P. (2026). Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study. PLOS One, 21(11), e0360957. https://doi.org/10.1371/journal.pone.0360957

Vancouver

Bui ACM, Nguyen QTN, Bui ANM, Ha MVP, Nguyen NP, Nguyen THA, et al. Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study. PLOS One. 2026;21(11):e0360957. doi:10.1371/journal.pone.0360957

BibTeX
@article{Bui2026,
  author = {Bui, Ai Cao My and Nguyen, Quynh Tran Nhat and Bui, Anh Ngoc Minh and Ha, Minh Vu Phuc and Nguyen, Nhan Phu and Nguyen, Thy Ha Anh and Dang, Nhan Quoc and Tran, Phuong Minh and Kha, Tu Vu and Nguyen, Nhu Dong Phuong and Le, Liem Diep Bao and Tran, Huy Hoai and Bui, Dung The and Nguyen, Nghia Phu},
  title = {Compare 30-minute automated office blood pressure vs 24-hour ambulatory blood pressure monitoring: A prospective study},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {11},
  pages = {e0360957},
  doi = {10.1371/journal.pone.0360957}
}
Kostenlos starten →