EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimizing the lighting environment in college teaching buildings in the Changsha-Zhuzhou-Xiangtan region based on hybrid lighting patterns

Leyan Zhang iD, Bi'nan Zuo, Xi Jin iD, Canlong Liu, Yufeng He

PLOS One · 2026

DOI: 10.1371/journal.pone.0359574 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Leyan Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Architecture, Hunan University of Science and Technology, School of Architecture and Design, Xiangtan, China. Hauptthemen laut MEDLINE: Lighting, Facility Design and Construction. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hunan Office of Philosophy and Social Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the rapid expansion of higher education campuses in China, teaching buildings have become major contributors to lighting-related energy consumption. Most university teaching buildings adopt interior corridor layouts, in which classrooms rely primarily on single-sided daylighting, often resulting in insufficient daylight availability, particularly in north-facing spaces. Improving the lighting performance of interior corridor–type teaching buildings is therefore critical for enhancing energy efficiency and indoor environmental quality. In this study, an evaluation framework for indoor lighting environments is established, and the Chongye Teaching Building at Hunan University of Technology is selected as a representative case. Through a combination of on-site measurements and daylighting simulations, the daylighting characteristics of interior corridor–type teaching buildings in the Changsha–Zhuzhou–Xiangtan (Chang–Zhu–Tan) region are systematically analyzed. Four hybrid lighting patterns integrating natural and artificial lighting are proposed, including High-Density Layout (HDL), Medium-Density Layout (MDL), Low-Density Layout (LDL), and Targeted Layout (TL). The results indicate that all four patterns significantly enhanced daylight utilization across multiple metrics—including illuminance, spatial uniformity, daylight factor, spatial daylight autonomy, and target illuminance duration—thereby reducing dependence on electric lighting during daytime classroom operation. Through this proof of concept, the present study provides guidance and references for optimizing the luminous environment in interior-corridor classrooms under comparable architectural and daylight climate conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LightingFacility Design and ConstructionChinaUniversitiesWorking ConditionsHumansAcademiaTeaching

Autor:innen und Institutionen

  • Department of Architecture, Hunan University of Science and Technology, School of Architecture and Design, Xiangtan, China.
  • Department of Architecture, Hunan University of Technology, School of Civil and Environmental Engineering, Zhuzhou, China.

ORCID-Profile: Leyan Zhang, Xi Jin

Förderung

  • Hunan Office of Philosophy and Social Science

Zitieren

APA

Zhang, L., Zuo, B., Jin, X., Liu, C., & He, Y. (2026). Optimizing the lighting environment in college teaching buildings in the Changsha-Zhuzhou-Xiangtan region based on hybrid lighting patterns. PLOS One. https://doi.org/10.1371/journal.pone.0359574

Vancouver

Zhang L, Zuo B, Jin X, Liu C, He Y. Optimizing the lighting environment in college teaching buildings in the Changsha-Zhuzhou-Xiangtan region based on hybrid lighting patterns. PLOS One. 2026. doi:10.1371/journal.pone.0359574

BibTeX
@article{Zhang2026,
  author = {Zhang, Leyan and Zuo, Bi'nan and Jin, Xi and Liu, Canlong and He, Yufeng},
  title = {Optimizing the lighting environment in college teaching buildings in the Changsha-Zhuzhou-Xiangtan region based on hybrid lighting patterns},
  journal = {PLOS One},
  year = {2026},
  doi = {10.1371/journal.pone.0359574}
}
Kostenlos starten →