Using a Stifneck Select CollarTM for hands-free semiautomatic blood flow measurements: A user study
PLOS One · 2026
DOI: 10.1371/journal.pone.0358589 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Reinhard Fuchs und 8 weiteren Autor:innen. Beteiligte Einrichtung: Innovation Center Computer Assisted Surgery (ICCAS), Medical Faculty, Leipzig University, Leipzig, Germany. Hauptthemen laut MEDLINE: Ultrasonography, Doppler, Cardiopulmonary Resuscitation. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Wirtschaft und Energie, Deutsche Herzstiftung, Bundesministerium für Forschung, Technologie und Raumfahrt.
Abstract (Originalsprache)
The percentage of long-term survival in out‑of‑hospital cardiac arrest cases is remarkably low. One approach would be to increase the effectiveness of cardiopulmonary resuscitation (CPR), which is currently not measurable in a quantifiable way. The most significant challenge in providing a mobile solution for CPR evaluation is a mobile, hazard‑free sensor attachment with high usability. We present a sensor attachment solution usable for semiautomatic ultrasonic (US) Doppler measurements. Components are attached to a Stifneck Select Collar™ (Laerdal). An inflatable cushion (TR-Band™, Terumo) allows adjustable contact pressure. A clinical study was conducted in which the system was evaluated based on comfort, pain, sensor support, the viability of Doppler signals, and the absence of skin irritations. The system was utilized in a prospective study involving 102 healthy probands. On a scale between 1 (Low) and 10 (Intense), ratings were 1.19 (SD 0.46), 6.52 (SD 1.78), and 9.95 (SD 0.32) for pain, comfort, and support, respectively. The average duration of application was 31.19 minutes (SD 16.75 minutes). Audible Doppler signals were achieved in 92.2% of the probands, and Doppler curve evaluation was usable in 73.5%. No skin irritations were observed. A hands‑free sensor attachment for a US probe was developed that caused no significant complaints by healthy study volunteers. Medical users assessed its attachment as robust. With its adjustable positioning and easy attachment, the Stifneck modification can form a basis for a mobile US Doppler device, capable of evaluating carotid artery flow during CPR.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Innovation Center Computer Assisted Surgery (ICCAS), Medical Faculty, Leipzig University, Leipzig, Germany.
- Klinik und Poliklinik für Kardiologie, Universitätsklinikum Leipzig, Leipzig, Germany.
- GAMPT mbH, Merseburg, Germany.
ORCID-Profile: Reinhard Fuchs, Karsten Lenk
Förderung
- Bundesministerium für Wirtschaft und Energie
- Deutsche Herzstiftung
- Bundesministerium für Forschung, Technologie und Raumfahrt
- Open Access Publishing Fund of Leipzig University
Zitieren
APA
Fuchs, R., Sumrah, N., Möbius-Winkler, M. N., Stachel, G., Schultz, M., Laufs, U., Neumuth, T., Unger, M., & Lenk, K. (2026). Using a Stifneck Select CollarTM for hands-free semiautomatic blood flow measurements: A user study. PLOS One. https://doi.org/10.1371/journal.pone.0358589
Vancouver
Fuchs R, Sumrah N, Möbius-Winkler MN, Stachel G, Schultz M, Laufs U, et al. Using a Stifneck Select CollarTM for hands-free semiautomatic blood flow measurements: A user study. PLOS One. 2026. doi:10.1371/journal.pone.0358589
BibTeX
@article{Fuchs2026,
author = {Fuchs, Reinhard and Sumrah, Nathalie and Möbius-Winkler, Maximilian N and Stachel, Georg and Schultz, Michael and Laufs, Ulrich and Neumuth, Thomas and Unger, Michael and Lenk, Karsten},
title = {Using a Stifneck Select CollarTM for hands-free semiautomatic blood flow measurements: A user study},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0358589}
}
EUVIMED