Development of a multiplex real-time PCR assay with fluorescence probe-melting-curve analysis for one-tube detection of respiratory pathogens
PLOS One · 2026
DOI: 10.1371/journal.pone.0357377 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Mingyu Ji und 4 weiteren Autor:innen. Beteiligte Einrichtung: Medical Integration and Practice Center, Shandong University, Jinan, Shandong, China. Hauptthemen laut MEDLINE: Multiplex Polymerase Chain Reaction, Respiratory Tract Infections, Real-Time Polymerase Chain Reaction. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Development Program of Jinan Municipal Health Commission.
Abstract (Originalsprache)
Pathogens causing respiratory infections have reemerged globally since the COVID-19 pandemic. Rapid and accurate identification of respiratory pathogens is critical for diagnosis and treatment. In this study, we developed and evaluated a multiplex real-time PCR assay with a fluorescence probe melting curve (mqPCR-PMC) assay to simultaneously detect six common pathogens, namely, influenza virus A and B (IFV-A and -B), respiratory syncytial virus (RSV), human rhinovirus (HRV), human adenovirus (HAdV) and Mycoplasma pneumoniae (MP). The primers and probes optimized in this assay exhibited a specificity of 100% with a panel of 57 pathogens. The detection limits of the assay ranged from 248 copies/ml to 394 copies/ml. Moreover, the coefficients of variation ranged from 0.11% to 0.30% for Tm and from 1.59% to 4.10% for Rm. The clinical accuracy of the assay was validated using 760 pharyngeal samples. Compared with a commercial kit based on conventional fluorescence RT-PCR, the assay showed more than 87% sensitivity and 99% specificity for each pathogen. The kappa values ranged from 0.927 to 1.000. Moreover, the assay was more precise for HRV and more sensitive on IFV-A, HAdV, MP and RSV. In summary, the mqPCR-PMC assay was demonstrated to be highly sensitive, highly specific and high throughput, and has potential for clinical use in respiratory infectious disease diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Medical Integration and Practice Center, Shandong University, Jinan, Shandong, China.
- Medical Research and Laboratory Diagnostic Center, Jinan Central Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
- Research and Development Department, GuoRan Gene Technology (Shandong) Company Limited, Jinan, Shandong, China.
- Shandong LaiBo Biotechnology Company Limited, Jinan, Shandong, China.
ORCID-Profile: Yunshan Wang, Qianqian Zhao
Förderung
- Science and Technology Development Program of Jinan Municipal Health Commission
Zitieren
APA
Ji, M., Dong, H., Xu, Y., Wang, Y., & Zhao, Q. (2026). Development of a multiplex real-time PCR assay with fluorescence probe-melting-curve analysis for one-tube detection of respiratory pathogens. PLOS One. https://doi.org/10.1371/journal.pone.0357377
Vancouver
Ji M, Dong H, Xu Y, Wang Y, Zhao Q. Development of a multiplex real-time PCR assay with fluorescence probe-melting-curve analysis for one-tube detection of respiratory pathogens. PLOS One. 2026. doi:10.1371/journal.pone.0357377
BibTeX
@article{Ji2026,
author = {Ji, Mingyu and Dong, Hongjiao and Xu, Yihui and Wang, Yunshan and Zhao, Qianqian},
title = {Development of a multiplex real-time PCR assay with fluorescence probe-melting-curve analysis for one-tube detection of respiratory pathogens},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0357377}
}
EUVIMED