EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-power pulsed-laser ablation of aluminum alloy: Simulation model and experimental validation

Qimeng Chen, Boxiang Hou iD, Yan Li, Zhe Wang, Jian Zhao, Keyan Dong

PLOS One · 2026

DOI: 10.1371/journal.pone.0357262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Qimeng Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Changchun University of Science and Technology The School of Electro-Optical Engineering, Changchun, Jilin, China. Hauptthemen laut MEDLINE: Aluminum, Alloys, Lasers, Models, Theoretical. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Major Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the critical influence of pulse shape on the laser ablation of metallic materials, this study proposes a comprehensive methodology that integrates finite‑element numerical simulations with experimental validation. Based on the spatiotemporal energy‑distribution characteristics of Gaussian and super‑Gaussian pulses, the temperature evolution, plasma electron density, and ablation efficiency of 6061 aluminum alloy were systematically analyzed under various single‑pulse energies and spot radii. Comparison between experimental measurements and numerical predictions enables the construction of an energy‑coupling model for laser ablation and establishes a theoretical framework describing how pulse shape governs the material’s thermal response and plasma dynamics. The performance of the experimental laser was benchmarked against that of a commercial laser. The results show that the maximum difference in dispersion coefficients between the two lasers is only 0.19%, and the largest discrepancy in average perforation time between the Gaussian and super‑Gaussian pulses is approximately 6 s. Owing to its more uniform energy distribution, the super‑Gaussian pulse exhibits 3–18% higher energy‑coupling efficiency and material‑removal efficiency under identical energy input. Therefore, controlling the pulse shape can significantly enhance the stability and efficiency of laser ablation, satisfy the requirements of high‑precision material processing regarding energy‑distribution uniformity and ablation consistency, and provide a theoretical foundation for applying pulse‑shaping techniques in high‑efficiency laser manufacturing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AluminumAlloysLasersModels, TheoreticalLaser TherapyComputer SimulationTemperature

Substanzen

AluminumAlloys

Autor:innen und Institutionen

  • Changchun University of Science and Technology The School of Electro-Optical Engineering, Changchun, Jilin, China.
  • Changchun Jingyi Optoelectronics Technology Company, Changchun, Jilin, China.

ORCID-Profile: Boxiang Hou

Förderung

  • National Science and Technology Major Project

Zitieren

APA

Chen, Q., Hou, B., Li, Y., Wang, Z., Zhao, J., & Dong, K. (2026). High-power pulsed-laser ablation of aluminum alloy: Simulation model and experimental validation. PLOS One. https://doi.org/10.1371/journal.pone.0357262

Vancouver

Chen Q, Hou B, Li Y, Wang Z, Zhao J, Dong K. High-power pulsed-laser ablation of aluminum alloy: Simulation model and experimental validation. PLOS One. 2026. doi:10.1371/journal.pone.0357262

BibTeX
@article{Chen2026,
  author = {Chen, Qimeng and Hou, Boxiang and Li, Yan and Wang, Zhe and Zhao, Jian and Dong, Keyan},
  title = {High-power pulsed-laser ablation of aluminum alloy: Simulation model and experimental validation},
  journal = {PLOS One},
  year = {2026},
  doi = {10.1371/journal.pone.0357262}
}
Kostenlos starten →