Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study
PLOS One · 2026
DOI: 10.1371/journal.pone.0357020 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift PLOS One, 2026. Verfasst von Jiyoung Emily Lee und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. Hauptthemen laut MEDLINE: Tears, Lipids, Meibomian Glands, Meibomian Gland Dysfunction. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Meibomian gland (MG) dysfunction impairs the tear film lipid layer, which is critical for preventing aqueous evaporation and maintaining tear film stability. While a LipiView® II-reported mean lipid layer thickness (LLT) of ≥100 nm indicates a high- or ceiling-range device output rather than a calibrated absolute LLT, mean LLT alone may overlook clinically relevant information about the dynamic behavior of the tear film. This study aimed to evaluate whether qualitative variability in 20-s LipiView® II dynamic LLT traces is associated with MG morphology and ocular surface findings in eyes with device-reported high-range LLT values. In this retrospective, cross-sectional study, we analyzed 20-s dynamic LipiView® II recordings from eyes that were initially measured to have a mean LLT of ≥100 nm. Two masked observers classified LLT pattern variability as high or low based on predefined criteria. Clinical and demographic differences between the high- and low-variability groups were assessed statistically. Out of 85 eyes, 58 (68.2%) and 27 (31.8%) exhibited high- and low-variability, respectively. The high-variability group demonstrated markedly elevated meiboscores compared to the low-variability group, indicating a greater degree of MG dropouts ( p = 0.042). Besides elevated meiboscores, patients in the high-variability group suffered from substantially worse dry eye disease (DED) symptoms, a trend toward higher corneal and conjunctival staining scores, and significantly increased blinking frequency ( p < 0.05). Qualitative evaluation of LLT revealed increased meiboscores, greater severity of DED symptoms, and increased blinking frequency even in eyes with device-reported high-range mean LLT. LLT pattern analysis may warrant evaluation as an adjunctive approach for the early detection and targeted management of MG dysfunction-related evaporative DED.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Itoh Clinic, Saitama, Japan.
- Department of Ophthalmology, Keio University, Tokyo, Japan.
ORCID-Profile: Jiyoung Emily Lee, Eun Chul Kim, Kyung-Sun Na
Förderung
- National Research Foundation of Korea
Zitieren
APA
Lee, J. E., Kim, D. K., Yoon, H. Y., Whang, W. J., Hwang, H. S., Kim, H. S., Arita, R., Kim, E. C., & Na, K. S. (2026). Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study. PLOS One. https://doi.org/10.1371/journal.pone.0357020
Vancouver
Lee JE, Kim DK, Yoon HY, Whang WJ, Hwang HS, Kim HS, et al. Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study. PLOS One. 2026. doi:10.1371/journal.pone.0357020
BibTeX
@article{Lee2026,
author = {Lee, Jiyoung Emily and Kim, Dong-Kyu and Yoon, Hye Yeon and Whang, Woong-Joo and Hwang, Ho Sik and Kim, Hyun-Seung and Arita, Reiko and Kim, Eun Chul and Na, Kyung-Sun},
title = {Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0357020}
}
EUVIMED