An insulator defect detection method for transmission lines in complex weather conditions based on improved YOLOv8n
PLOS One · 2026
DOI: 10.1371/journal.pone.0356260 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Xiuyang Yuan und 4 weiteren Autor:innen. Beteiligte Einrichtung: China Three Gorges University, Yichang, Hubei, China. Hauptthemen laut MEDLINE: Weather, Unmanned Aerial Devices, Image Processing, Computer-Assisted. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Science and Technology Project of State Grid Power Space Technology Co., Ltd..
Abstract (Originalsprache)
Addressing challenges in UAV power line inspection—where insulator defect detection models are prone to environmental interference, insufficient feature representation, and difficulty balancing lightweight requirements—this study develops a lightweight image defect detection model that integrates high accuracy with strong robustness. An enhanced algorithm based on YOLOv8n is proposed. MobileNetV4 is adopted as the lightweight backbone, CBAM is introduced to enhance defect feature representation, ABIFPN is designed for multiscale bidirectional feature fusion, and SIoU is employed to improve localization accuracy. A multi-weather dataset containing 3,851 images of self-shattered and damaged insulators under rainy, snowy, foggy, overcast, and varying-exposure conditions was constructed using real and synthesized images. The dataset was divided into training, validation, and test sets at a ratio of 7:2:1. Across five independent experiments, the proposed model improved precision, recall, mAP@0.5, and mAP@0.5:0.95 by 2.43, 2.32, 2.43, and 5.47 percentage points, respectively, compared with the baseline. With a model size of only 7.01 MB, demonstrated better overall detection performance than YOLOv5n and YOLOv7-tiny. These results indicate its potential for UAV-mounted edge-based transmission-line inspection. However, some weather samples were synthetically generated, and more real-world data will be incorporated in future work.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- China Three Gorges University, Yichang, Hubei, China.
- Guoke Nengchuang (Beijing) Technology Co., Ltd., Beijing, China.
ORCID-Profile: Xiuyang Yuan
Förderung
- the Science and Technology Project of State Grid Power Space Technology Co., Ltd.
Zitieren
APA
Yuan, X., Shang, Z., Fang, J., Zhang, H., & Ou, Y. (2026). An insulator defect detection method for transmission lines in complex weather conditions based on improved YOLOv8n. PLOS One. https://doi.org/10.1371/journal.pone.0356260
Vancouver
Yuan X, Shang Z, Fang J, Zhang H, Ou Y. An insulator defect detection method for transmission lines in complex weather conditions based on improved YOLOv8n. PLOS One. 2026. doi:10.1371/journal.pone.0356260
BibTeX
@article{Yuan2026,
author = {Yuan, Xiuyang and Shang, Zhiyu and Fang, Jiaman and Zhang, Han and Ou, Yuhang},
title = {An insulator defect detection method for transmission lines in complex weather conditions based on improved YOLOv8n},