Evaluation of the accuracy of peri-operative CEUS in measuring the effect of microwave ablation treatment of uterine fibroids, in comparison with MRI
PLOS One · 2026
DOI: 10.1371/journal.pone.0356141 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS One, 2026. Verfasst von Marie Beermann und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Danderyd Hospital, Stockholm, Sweden. Hauptthemen laut MEDLINE: Leiomyoma, Magnetic Resonance Imaging, Microwaves, Uterine Neoplasms. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Karolinska Institutet.
Abstract (Originalsprache)
Objective
The objective of this study was to determine if peri-operative contrast enhanced ultrasound (CEUS) is as accurate as magnetic resonance imaging (MRI) in measuring the immediate effect of microwave ablation (MWA) treatment of uterine fibroids. Secondary outcomes were ablation ratio and proportion of recurrence of treated fibroids at 6 months.
Methods
The study was a prospective observational trial. Seventeen patients with symptomatic uterine fibroids were included and treated with percutaneous ultrasound guided microwave ablation. Before the ablation, the volume of the up to three largest fibroids were recorded with MRI and CEUS. At the end of operation, the ablated volume was recorded with CEUS and compared to MRI within a week. At 6 months, the ablated volume was again recorded with MRI and any sign of regrowth of the treated fibroid(s) was noted.
Results
A total of 19 fibroids were analyzed. The intraclass correlation coefficient (ICC) between ablation volume obtained by CEUS and MRI respectively was calculated to be 0.965 (95% confidence interval 0.909, 0.987). The Bland-Altman graph showed that the mean difference between volumes was –1.68 ml and standard deviation 22.60 ml, giving the limits of agreement (−45.98, 42.61). Regrowth of vascularized tissue was seen in 8 fibroids (47%).
Conclusion
CEUS can be used to evaluate ablation volume and ablation ratio and is useful for intraoperative estimation and guidance. It shows strong correlation with MRI. Regrowth of fibroids may occur even when initial treatment was technically successful.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Danderyd Hospital, Stockholm, Sweden.
- Department of Clinical Sciences, Danderyd Hospital, Karolinska Institutet, Stockholm, Sweden.
- Department of Obstetrics and Gynecology, Danderyd Hospital, Stockholm, Sweden.
ORCID-Profile: Marie Beermann
Förderung
- Karolinska Institutet
Zitieren
APA
Beermann, M., Jonsdottir, G., Cronsioe, A., Hasselrot, K., & Kopp-Kallner, H. (2026). Evaluation of the accuracy of peri-operative CEUS in measuring the effect of microwave ablation treatment of uterine fibroids, in comparison with MRI. PLOS One. https://doi.org/10.1371/journal.pone.0356141
Vancouver
Beermann M, Jonsdottir G, Cronsioe A, Hasselrot K, Kopp-Kallner H. Evaluation of the accuracy of peri-operative CEUS in measuring the effect of microwave ablation treatment of uterine fibroids, in comparison with MRI. PLOS One. 2026. doi:10.1371/journal.pone.0356141
BibTeX
@article{Beermann2026,
author = {Beermann, Marie and Jonsdottir, Gudny and Cronsioe, Annika and Hasselrot, Klara and Kopp-Kallner, Helena},
title = {Evaluation of the accuracy of peri-operative CEUS in measuring the effect of microwave ablation treatment of uterine fibroids, in comparison with MRI},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0356141}
}
EUVIMED