Synthetic data augmentation for CT-based emphysema subtype classification: A comparative evaluation of generative and classical approaches
PLOS One · 2026
DOI: 10.1371/journal.pone.0355850 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS One, 2026. Verfasst von Nicholas Dietrich und 1 weiteren Autor:innen. Beteiligte Einrichtung: Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Pulmonary Emphysema, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Data scarcity is a persistent challenge in medical image analysis. Synthetic data generation using deep generative models has been proposed as a potential approach to address this limitation, yet its performance in small-data settings remains poorly characterized. This study compared three class-conditional generative approaches, a conditional variational autoencoder (cVAE), a conditional shallow-decoder VAE variant (cSD-VAE), and a conditional Wasserstein GAN with gradient penalty (cWGAN-GP), against classical geometric augmentation for emphysema subtype classification on 168 CT patches (three classes: normal tissue, centrilobular emphysema, and paraseptal emphysema). Each method was evaluated at three synthetic-to-real ratios (0.5x, 1.0x, 2.0x) using patient-level 70/30 splits across 10 random seeds, with an ImageNet-pretrained ResNet18 as the downstream classifier. No individual augmentation strategy produced a statistically significant improvement in balanced accuracy over the unaugmented baseline (0.522 ± 0.067). The conditional WGAN-GP at 1.0x achieved the highest individual balanced accuracy (0.548 ± 0.068, Cohen’s d = 0.47 versus baseline), but did not reach statistical significance (p = 0.084). A pre-specified ensemble combining all four augmentation methods at the 1.0x multiplier did not significantly improve balanced accuracy over baseline (0.541 ± 0.088 versus 0.522 ± 0.067; Cohen’s d = 0.32, Wilcoxon p = 0.275). Neither pixel-space nor feature-space distributional fidelity was associated with downstream classification performance. Overall, no benefit was detected from class-conditional generative augmentation in this small-data, texture-driven setting. Future work should focus on improving generative modeling under small-data conditions, including task-aware objectives and pathology-constrained synthesis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.
- Faculty of Engineering, McMaster University, Hamilton, Ontario, Canada.
ORCID-Profile: Nicholas Dietrich, David McShannon
Zitieren
APA
Dietrich, N., & McShannon, D. (2026). Synthetic data augmentation for CT-based emphysema subtype classification: A comparative evaluation of generative and classical approaches. PLOS One. https://doi.org/10.1371/journal.pone.0355850
Vancouver
Dietrich N, McShannon D. Synthetic data augmentation for CT-based emphysema subtype classification: A comparative evaluation of generative and classical approaches. PLOS One. 2026. doi:10.1371/journal.pone.0355850
BibTeX
@article{Dietrich2026,
author = {Dietrich, Nicholas and McShannon, David},
title = {Synthetic data augmentation for CT-based emphysema subtype classification: A comparative evaluation of generative and classical approaches},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0355850}
}
EUVIMED