Diagnostic accuracy of automated hematology analyzer abnormal flags for detecting hematological malignancies: A systematic review and meta-analysis
PLOS One · 31.07.2026 · 21 (7) · e0354619
DOI: 10.1371/journal.pone.0354619 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift PLOS One, online erschienen am 31.07.2026. Verfasst von Zewudu Mulatie und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Laboratory Sciences, College of Medicine and Health Sciences, Wollo University, Dessie, Ethiopia. Hauptthemen laut MEDLINE: Hematologic Neoplasms, Hematology. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Hematological malignancies including leukemia, lymphoma, and myelodysplastic syndromes, are characterized by clonal proliferation of abnormal blood or bone marrow cells. Early and accurate detection is essential for improving treatment outcomes and survival. Automated hematology analyzers generate abnormal flags that may indicate underlying hematologic malignancies; however, their overall diagnostic accuracy has not been comprehensively evaluated. This systematic review and meta-analysis aimed to assess the diagnostic performance of abnormal flags for detecting hematological malignancies.
Methods
A systematic search of PubMed, PubMed Central, Scopus, ScienceDirect, and Google Scholar was conducted to identify relevant diagnostic accuracy studies. Methodological quality was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2(QUADAS-2) tool. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated using a bivariate random-effects model in Stata version 17.0. Heterogeneity was assessed using the I 2 statistic, and subgroup and meta-regression analyses were performed to explore potential sources of variability.
Results
Twenty-eight studies met the inclusion criteria. The pooled sensitivity and specificity of abnormal hematology analyzer flags for detecting hematological malignancies were 91% (95% CI: 87%–94%) and 89% (95% CI: 84%–92%), respectively, indicating good diagnostic accuracy. Significant heterogeneity was observed across studies (I 2 > 50%). Meta-regression analysis identified the type of abnormal flag as a significant source of heterogeneity in sensitivity (p < 0.001), whereas both the type of abnormal flag and the analyzer platform significantly influenced specificity.
Conclusion
Automated hematology analyzer abnormal flags showed promising diagnostic performance. However, substantial heterogeneity and differences in analyzer platforms, flag types, and reference standards reduce the certainty and generalizability of pooled estimates. Nevertheless, these findings support the use of abnormal hematology analyzer flags as an effective initial screening tool in routine laboratory practice, particularly in resource-limited settings where rapid and cost-effective diagnostic support is essential.
Systematic review registration
PROSPERO (CRD42024601908 ).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Laboratory Sciences, College of Medicine and Health Sciences, Wollo University, Dessie, Ethiopia.
- School of Medical Laboratory Sciences, Asrat Weldeyes Health Science Campus, Debre Berhan University, Debre Berhan, Ethiopia.
- Department Hematology and immunohematology, School of Biomedical and Laboratory Science, College of Medicine and Health Science, University of Gondar, Gondar, Ethiopia.
ORCID-Profile: Zewudu Mulatie, Afewerk Habtamu
Zitieren
APA
Mulatie, Z., Eshetu, B., Habtamu, A., Desale, S., Sebsibe, S., Erkihun, Y., Kassa, Y., Gessese, T., Alebachew, M., Shimeles, M., Feyisa, M. S., & Berta, D. M. (2026). Diagnostic accuracy of automated hematology analyzer abnormal flags for detecting hematological malignancies: A systematic review and meta-analysis. PLOS One, 21(7), e0354619. https://doi.org/10.1371/journal.pone.0354619
Vancouver
Mulatie Z, Eshetu B, Habtamu A, Desale S, Sebsibe S, Erkihun Y, et al. Diagnostic accuracy of automated hematology analyzer abnormal flags for detecting hematological malignancies: A systematic review and meta-analysis. PLOS One. 2026;21(7):e0354619. doi:10.1371/journal.pone.0354619
BibTeX
@article{Mulatie2026,
author = {Mulatie, Zewudu and Eshetu, Bruktawit and Habtamu, Afewerk and Desale, Sisay and Sebsibe, Saleamlak and Erkihun, Yonas and Kassa, Yeshimebet and Gessese, Tesfaye and Alebachew, Mihreteab and Shimeles, Mikiyas and Feyisa, Mahider Shimelis and Berta, Dereje Mengesha},
title = {Diagnostic accuracy of automated hematology analyzer abnormal flags for detecting hematological malignancies: A systematic review and meta-analysis},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {7},
pages = {e0354619},
doi = {10.1371/journal.pone.0354619}
}
EUVIMED