EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of anemia in non-enhanced and contrast-enhanced dual-energy CT using electron density imaging

Cherry Kim iD, Suk Keu Yeom iD, Hangseok Choi iD, Euddeum Shim, Sung Ho Hwang, Hwan Seok Yong iD, Marly van Assen, Carlo N De Cecco, Hwa Jung Sung, Se Ryeon Lee

PLOS One · 02.07.2026 · 21 (7) · e0352504

DOI: 10.1371/journal.pone.0352504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 02.07.2026. Verfasst von Cherry Kim und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Anemia, Tomography, X-Ray Computed, Contrast Media. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Research Foundation of Korea (NRF) grant funded by the Korea government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electron density (ED) imaging derived from dual-energy CT (DECT) quantifies tissue composition and may reflect changes in red blood cell (RBC) mass associated with anemia. This study aimed to evaluate the utility of ED from DECT in assessing anemia severity using both non-enhanced CT (NECT) and contrast-enhanced CT (CECT), and to investigate its correlation with hemoglobin (Hb), hematocrit (Hct), and RBC count. In this retrospective study, 2,558 patients who underwent NECT and 2,545 who underwent CECT using a dual-layer spectral detector CT (Philips IQon) were included. Mean ED and mean CT attenuation (HU) were measured at five cardiac blood pool sites. Spearman’s rank correlation analysis was performed between CT measurements and hematologic parameters. Partial correlation analysis adjusting for age and sex and non-parametric bootstrap internal validation were also conducted. Receiver operating characteristic (ROC) curve analysis was performed to determine diagnostic cutoff values for anemia detection. Mean ED significantly decreased with increasing anemia severity in both NECT and CECT cohorts (all p < 0.001). With NECT, mean ED showed positive correlations with Hb, Hct, and RBC count (r s = 0.726–0.770), with AUCs of 0.825–0.956 for anemia detection. With CECT, mean ED retained positive correlations with hematologic parameters (r s = 0.447–0.583), with AUCs of 0.727–0.895, while mean HU showed no meaningful correlation. After adjustment for age and sex, partial correlation coefficients remained substantial (NECT: r s = 0.694; CECT: r s = 0.509 for Hb), and bootstrap internal validation confirmed negligible overfitting bias. ED derived from DECT demonstrated diagnostic utility for anemia detection on NECT, unlike conventional HU, retained clinically relevant associations with hematologic parameters on CECT. ED-based anemia detection on CECT is best conceptualized as opportunistic detection, particularly for severe anemia, supplementary to laboratory testing. These findings require external validation across diverse DECT platforms before broader clinical implementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnemiaTomography, X-Ray ComputedContrast MediaHumansFemaleMaleRetrospective StudiesAgedHematocritMiddle AgedROC CurveHemoglobinsErythrocyte Count

Substanzen

Contrast MediaHemoglobins

Autor:innen und Institutionen

  • Department of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
  • Department of Radiology, Ansan Hospital, Korea University College of Medicine, Ansan-si, Gyeonggi-do, South Korea.
  • Medical Science Research Center, Korea University College of Medicine, Goryeodae-ro, Seongbuk-gu, South Korea.
  • Department of Radiology, Anam Hospital, Korea University College of Medicine, Seoul, South Korea.
  • Department of Radiology, Guro Hospital, Korea University College of Medicine, Seoul, South Korea.
  • Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, United States of America.

ORCID-Profile: Cherry Kim, Suk Keu Yeom, Hangseok Choi, Hwan Seok Yong

Förderung

  • the National Research Foundation of Korea (NRF) grant funded by the Korea government

Zitieren

APA

Kim, C., Yeom, S. K., Choi, H., Shim, E., Hwang, S. H., Yong, H. S., van Assen, M., De Cecco, C. N., Sung, H. J., & Lee, S. R. (2026). Evaluation of anemia in non-enhanced and contrast-enhanced dual-energy CT using electron density imaging. PLOS One, 21(7), e0352504. https://doi.org/10.1371/journal.pone.0352504

Vancouver

Kim C, Yeom SK, Choi H, Shim E, Hwang SH, Yong HS, et al. Evaluation of anemia in non-enhanced and contrast-enhanced dual-energy CT using electron density imaging. PLOS One. 2026;21(7):e0352504. doi:10.1371/journal.pone.0352504

BibTeX
@article{Kim2026,
  author = {Kim, Cherry and Yeom, Suk Keu and Choi, Hangseok and Shim, Euddeum and Hwang, Sung Ho and Yong, Hwan Seok and van Assen, Marly and De Cecco, Carlo N and Sung, Hwa Jung and Lee, Se Ryeon},
  title = {Evaluation of anemia in non-enhanced and contrast-enhanced dual-energy CT using electron density imaging},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {7},
  pages = {e0352504},
  doi = {10.1371/journal.pone.0352504}
}
Kostenlos starten →