EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bacterial contamination of surgical instruments in 25-gauge pars plana vitrectomy: Incidence and risk factors

Fumiya Miyako iD, Yosuke Harada iD, Tomona Hiyama, Seiya Kashiyama, Saori Kawamoto, Chika Yokota, Akira Minamoto, Hiroki Ota, Ayako Sadahide, Kazuyuki Hirooka, Taiichiro Chikama, Hirokazu Sakaguchi iD

PLOS One · 28.05.2026 · 21 (5) · e0349663

DOI: 10.1371/journal.pone.0349663 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 28.05.2026. Verfasst von Fumiya Miyako und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, Hiroshima, Japan. Hauptthemen laut MEDLINE: Vitrectomy, Surgical Instruments, Equipment Contamination. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the incidence of surgical instrument contamination associated with microincision vitrectomy surgery.

Methods

Ninety-six eyes from 86 immunocompetent patients who underwent 25-gauge pars plana vitrectomy from December 2023 to February 2024 in our institution were retrospectively analyzed.

Results

Surgical instrument contamination was detected in 7 cases (7.3%). Bacterial species were isolated from the trocar, endoilluminator, and beveled probe. Postoperative endophthalmitis did not occur during the 2-month follow-up period. Use of preoperative antibacterial eye drops was significantly associated with lower risk of bacterial contamination.

Conclusion

Contamination may occur 25-gauge pars plana vitrectomy, even when preoperative antibacterial eye drops are used in conjunction with povidone-iodine irrigation and adequate vitreous dissection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VitrectomySurgical InstrumentsEquipment ContaminationHumansIncidenceRisk FactorsRetrospective StudiesFemaleEndophthalmitisBacteriaAnti-Bacterial Agents

Substanzen

Anti-Bacterial Agents

Autor:innen und Institutionen

  • Department of Ophthalmology and Visual Science, Hiroshima University Graduate School of Biomedical Sciences, Hiroshima, Japan.
  • Department of Clinical Support, Clinical Laboratory Division, Hiroshima University‌‌, Hiroshima, Japan.

ORCID-Profile: Fumiya Miyako, Yosuke Harada, Hirokazu Sakaguchi

Zitieren

APA

Miyako, F., Harada, Y., Hiyama, T., Kashiyama, S., Kawamoto, S., Yokota, C., Minamoto, A., Ota, H., Sadahide, A., Hirooka, K., Chikama, T., & Sakaguchi, H. (2026). Bacterial contamination of surgical instruments in 25-gauge pars plana vitrectomy: Incidence and risk factors. PLOS One, 21(5), e0349663. https://doi.org/10.1371/journal.pone.0349663

Vancouver

Miyako F, Harada Y, Hiyama T, Kashiyama S, Kawamoto S, Yokota C, et al. Bacterial contamination of surgical instruments in 25-gauge pars plana vitrectomy: Incidence and risk factors. PLOS One. 2026;21(5):e0349663. doi:10.1371/journal.pone.0349663

BibTeX
@article{Miyako2026,
  author = {Miyako, Fumiya and Harada, Yosuke and Hiyama, Tomona and Kashiyama, Seiya and Kawamoto, Saori and Yokota, Chika and Minamoto, Akira and Ota, Hiroki and Sadahide, Ayako and Hirooka, Kazuyuki and Chikama, Taiichiro and Sakaguchi, Hirokazu},
  title = {Bacterial contamination of surgical instruments in 25-gauge pars plana vitrectomy: Incidence and risk factors},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {5},
  pages = {e0349663},
  doi = {10.1371/journal.pone.0349663}
}
Kostenlos starten →