EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Measurement properties of the 30-second sit-to-stand test in post COVID-19 condition: Results from the PYCNOVID randomised controlled trial

Julia Braun, Julia Kopp, Lisa Künzi, Milo A Puhan, Jan S Fehr, Thomas Radtke iD

PLOS One · 12.05.2026 · 21 (5) · e0348275

DOI: 10.1371/journal.pone.0348275 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift PLOS One, online erschienen am 12.05.2026. Verfasst von Julia Braun und 5 weiteren Autor:innen. Beteiligte Einrichtung: Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zürich, Switzerland. Hauptthemen laut MEDLINE: COVID-19, Exercise Test. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horphag Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The 30-second sit-to-stand test (30s-STS) is a frequently used measure of functional capacity in post-COVID-19 condition (PCC), but its measurement properties have not been comprehensively investigated.

Methods

We used data from the PYCNOVID randomised controlled trial to examine feasibility, safety, test-retest reliability, construct validity (correlations with key symptoms and physical activity), and responsiveness to change of the 30s-STS. Data were collected at screening, at baseline (approximately 2 weeks after screening), and at follow-up (12 weeks after baseline). Using screening and baseline data, agreement was evaluated using Bland-Altman analysis (mean bias and limits of agreement), alongside the intraclass correlation coefficient (ICC) and the minimal detectable change (MDC95). Correlation coefficients were used to assess relationships between the 30s-STS test, physical activity, and key PCC-related symptoms. The minimal important difference (MID) was estimated with data from baseline and at 12-weeks using anchor- and distribution-based methods.

Results

Data from 150 adults with PCC (74.7% female) were analysed. The 30s-STS was safe (no adverse event) and feasible. Overall, test performance was reduced, 46% of participants had z-score values below the 5 th percentile. The test showed good test-retest reliability (ICC 0.82 [95% CI, 0.76 to 0.86]) with no indication for a systematic learning effect; however, the limits of agreement were wide. Mean bias between was 0.84 repetitions (95% CI, 0.26 to 1.42). The MDC95 was 4.25 repetitions. Correlations with physical activity and key PCC-related symptoms were weak. Distribution-based methods yielded MID values between 1.38 and 3.23 repetitions. Change correlations between 30s-STS repetitions and the anchors were insufficient for anchor-based MID calculation.

Conclusions

The 30s-STS test is feasible, safe, and demonstrates good test-retest reliability. Changes exceeding four repetitions surpass measurement error (MDC95), while distribution-based estimates suggest a provisional MID of two repetitions. Further studies are needed to establish a triangulated MID to better capture patient-relevant change.

Trial registration

ClinicalTrials.gov, NCT05890534 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19Exercise TestHumansFemaleReproducibility of ResultsMaleMiddle AgedSARS-CoV-2AdultPost-Acute COVID-19 SyndromeExercisePandemics

Autor:innen und Institutionen

  • Epidemiology, Biostatistics and Prevention Institute, University of Zurich, Zürich, Switzerland.

ORCID-Profile: Thomas Radtke

Förderung

  • Horphag Research

Zitieren

APA

Braun, J., Kopp, J., Künzi, L., Puhan, M. A., Fehr, J. S., & Radtke, T. (2026). Measurement properties of the 30-second sit-to-stand test in post COVID-19 condition: Results from the PYCNOVID randomised controlled trial. PLOS One, 21(5), e0348275. https://doi.org/10.1371/journal.pone.0348275

Vancouver

Braun J, Kopp J, Künzi L, Puhan MA, Fehr JS, Radtke T. Measurement properties of the 30-second sit-to-stand test in post COVID-19 condition: Results from the PYCNOVID randomised controlled trial. PLOS One. 2026;21(5):e0348275. doi:10.1371/journal.pone.0348275

BibTeX
@article{Braun2026,
  author = {Braun, Julia and Kopp, Julia and Künzi, Lisa and Puhan, Milo A and Fehr, Jan S and Radtke, Thomas},
  title = {Measurement properties of the 30-second sit-to-stand test in post COVID-19 condition: Results from the PYCNOVID randomised controlled trial},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {5},
  pages = {e0348275},
  doi = {10.1371/journal.pone.0348275}
}
Kostenlos starten →