EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Direct LAMP for on-site rapid detection of Vibrio parahaemolyticus in shrimp (Litopenaeus vannamei) aquaculture water

Xiaodan Pu, Feng Lu, Qianqian Yang, Zhenyu Han, Xueting Zhu, Jianlei Chen, Dahai Zhang, Xuzhi Zhang iD

PLOS One · 29.04.2026 · 21 (4) · e0348231

DOI: 10.1371/journal.pone.0348231 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 29.04.2026. Verfasst von Xiaodan Pu und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Food Science and Technology, Shanghai Ocean University, Shanghai, China. Hauptthemen laut MEDLINE: Vibrio parahaemolyticus, Aquaculture, Penaeidae, Nucleic Acid Amplification Techniques. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the national Key R&D Program of China, the state key laboratory of mariculture biobreeding and sustainable goods, the Science and Technology Project of Shinan District, Qingdao.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Effective on-site surveillance of pathogens in aquaculture environments via loop-mediated isothermal amplification (LAMP) remains challenging due to the impractical and time-intensive DNA extraction required in field settings. In this study, a DNA extraction-free approach, i.e., direct LAMP (dLAMP), was evaluated, additionally concerning key physicochemical inhibitors derived from real, complex aquaculture water matrices. Eight representative water samples were collected from Litopenaeus vannamei aquaculture systems, encompassing broad ranges of salinity (7.61‰–32.88‰), pH (6.98–8.41), chemical oxygen demand (COD: 6.00–12.25 mg/L), soluble reactive phosphate (SRP: 0.13–1.24 mg/L), dissolved inorganic nitrogen (DIN: 0.67–3.09 mg/L), and total suspended solids (TSS: 133–737 mg/L). Boiled aquaculture water samples served directly as DNA templates for the LAMP detection of Vibrio parahaemolyticus with tlh gene. While pH, COD, SRP, DIN, and TSS had negligible effects on amplification efficiency, elevated salinity was found to significantly reduce assay sensitivity. Adjusting the salinity using deionized water to ≤ 10.00‰ effectively mitigates its inhibitory effect. Under optimized conditions, 10 µL of boiled aquaculture water was sufficient for reliable detection without compromising sensitivity or specificity. The detection limit was determined to be 10 2 CFU/mL (with a detection probability of 67%). Using DNA dye GeneFinder™ to show amplicon visually, the entire workflow, including sampling, salinity adjustment (if needed), boiling, chilling, and isothermal incubation, required no more than 1 h. This dLAMP method requires no specialized equipment beyond a portable heater, demonstrating a strong potential for point-of-care applications, and enabling practical field surveillance of pathogens in aquaculture water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vibrio parahaemolyticusAquaculturePenaeidaeNucleic Acid Amplification TechniquesWater MicrobiologyAnimalsDNA, BacterialSalinityHydrogen-Ion ConcentrationMolecular Diagnostic Techniques

Substanzen

DNA, Bacterial

Autor:innen und Institutionen

  • College of Food Science and Technology, Shanghai Ocean University, Shanghai, China.
  • State Key Laboratory of Mariculture Biobreeding and Sustainable Goods, Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao, China.
  • Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, China.
  • International Department, Qingdao No. 58 High School, Qingdao, China.

ORCID-Profile: Xuzhi Zhang

Förderung

  • the national Key R&D Program of China
  • the state key laboratory of mariculture biobreeding and sustainable goods
  • the Science and Technology Project of Shinan District, Qingdao

Zitieren

APA

Pu, X., Lu, F., Yang, Q., Han, Z., Zhu, X., Chen, J., Zhang, D., & Zhang, X. (2026). Direct LAMP for on-site rapid detection of Vibrio parahaemolyticus in shrimp (Litopenaeus vannamei) aquaculture water. PLOS One, 21(4), e0348231. https://doi.org/10.1371/journal.pone.0348231

Vancouver

Pu X, Lu F, Yang Q, Han Z, Zhu X, Chen J, et al. Direct LAMP for on-site rapid detection of Vibrio parahaemolyticus in shrimp (Litopenaeus vannamei) aquaculture water. PLOS One. 2026;21(4):e0348231. doi:10.1371/journal.pone.0348231

BibTeX
@article{Pu2026,
  author = {Pu, Xiaodan and Lu, Feng and Yang, Qianqian and Han, Zhenyu and Zhu, Xueting and Chen, Jianlei and Zhang, Dahai and Zhang, Xuzhi},
  title = {Direct LAMP for on-site rapid detection of Vibrio parahaemolyticus in shrimp (Litopenaeus vannamei) aquaculture water},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {4},
  pages = {e0348231},
  doi = {10.1371/journal.pone.0348231}
}
Kostenlos starten →