Normal values of femoral head coverage angles on three-dimensional computed tomography images
PLOS One · 2026
DOI: 10.1371/journal.pone.0347008 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Seohyun Choi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, College of Medicine, Gachon University, Incheon, Republic of Korea. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Femur Head, Imaging, Three-Dimensional. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Gyeonggi-do Regional Research Center.
Abstract (Originalsprache)
Introduction
Identifying novel diagnostic parameters is essential to address the inaccuracies related to femoral head coverage angle measurements using conventional methods. This study aimed to propose new femoral head coverage landmarks on 3D pelvic CT images in a Korean population and to present reference values based on these landmarks.
Methods
This single-center retrospective cohort study defined the center, lateral, anterior, and posterior margins of the acetabulum from three-dimensional (3D) pelvic computed tomography (CT) scans of healthy Korean individuals. The lateral center-edge angle (LCEA), anterior center-edge angle (ACEA), posterior center-edge angle (PCEA), anterior acetabular sector angle (AASA), and posterior acetabular sector angle (PASA) were measured in 3D space.
Results
The normal values for 3D LCEA in Korean males and females were 34.8° (SD = 8.3°) and 32.0° (SD = 6.9°), respectively. The 3D angles measured showed significant variations according to sex and age, with center-edge angles (LCEA, ACEA, and PCEA) generally increasing with age, whereas sector angles (AASA and PASA) showed a decreasing trend.
Conclusion
The standardized values and statistical findings based on sex and age provided in this study offer valuable references for guiding surgical interventions in the acetabulum. Also, the proposed method yielded more likely to be reliable results than traditional two-dimensional methods with substantial differences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medicine, College of Medicine, Gachon University, Incheon, Republic of Korea.
- Medical Devices R&D Center, Gachon University Gil Medical Center, Incheon, Republic of Korea.
- Department of Biohealth & Medical Engineering, Gachon University, Seongnam-si, Gyeonggi-do, Republic of Korea.
- Biomedical & Convergence Institute, Gil Medical Center, Gachon University, Incheon, Republic of Korea.
- Orthopedic Trauma Division, Trauma Center, Gachon University College of Medicine, Namdong-gu, Incheon, Republic of Korea.
- Department of Biomedical Engineering, Gil Medical Center, College of Medicine, Gachon University, Incheon, Republic of Korea.
ORCID-Profile: Kwang Gi Kim
Förderung
- Gyeonggi-do Regional Research Center
Zitieren
APA
Choi, S., Lee, S. M., Kim, Y. J., Yoon, Y. C., & Kim, K. G. (2026). Normal values of femoral head coverage angles on three-dimensional computed tomography images. PLOS One. https://doi.org/10.1371/journal.pone.0347008
Vancouver
Choi S, Lee SM, Kim YJ, Yoon YC, Kim KG. Normal values of femoral head coverage angles on three-dimensional computed tomography images. PLOS One. 2026. doi:10.1371/journal.pone.0347008
BibTeX
@article{Choi2026,
author = {Choi, Seohyun and Lee, Seon Min and Kim, Young Jae and Yoon, Yong-Cheol and Kim, Kwang Gi},
title = {Normal values of femoral head coverage angles on three-dimensional computed tomography images},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0347008}
}
EUVIMED