EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Development and initial validation of a computerized adaptive test prototype for ECG interpretation using item response theory

Shinji Inaba iD, Kazumichi Yamamoto, Tomohiro Kaga, Hiroshi Kawakami iD, Mohammad Zahidul Islam, Muhammad Wannous, Masatsugu Sakata, Toshi A Furukawa, Osamu Yamaguchi

PLOS One · 17.07.2026 · 21 (7) · e0344341

DOI: 10.1371/journal.pone.0344341 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift PLOS One, online erschienen am 17.07.2026. Verfasst von Shinji Inaba und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan. Hauptthemen laut MEDLINE: Electrocardiography. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: industrial seeds support from Ehime University, health care science institute.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Accurate electrocardiogram (ECG) interpretation is essential for appropriate clinical decision-making, yet competency remains suboptimal among many healthcare professionals. Although computerized adaptive testing (CAT) has the potential to provide rapid, individualized, and standardized assessment of ECG interpretation skills, its implementation requires a well-calibrated item bank based on item response theory. This study aimed to establish item parameters, evaluate the latent structure underlying ECG interpretation competency using multidimensional item response theory (MIRT), and develop an initial CAT prototype for ECG competency assessment. Methods and results We analyzed responses from 535 healthcare professionals who completed a 50-item online ECG test previously developed and administered via an online platform. Participants represented diverse clinical roles and experience levels. Dimensionality was examined using exploratory and confirmatory MIRT analyses. A unidimensional model and a two-factor model both emerged as plausible latent structures. Item parameters, including discrimination and difficulty, were estimated from item characteristic curves. Of 50 items, 47 demonstrated strong discrimination, and difficulty parameters were appropriately distributed. Model fit analyses demonstrated that the selected model adequately represented the response data and provided a suitable basis for CAT development.

Conclusions

Although both unidimensional and two-factor models demonstrated acceptable statistical performance, the unidimensional model was selected as the initial operational framework because of its simplicity and suitability for computerized adaptive testing. The calibrated ECG item bank enabled development of a preliminary CAT prototype. These findings support the feasibility of CAT as an efficient and standardized approach for assessing ECG interpretation competency across healthcare professionals. Further studies are warranted to validate its performance and educational utility in broader clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyHumansFemaleClinical CompetenceHealth Personnel

Autor:innen und Institutionen

  • Department of Cardiology, Pulmonology, Hypertension and Nephrology, Ehime University Graduate School of Medicine, Toon, Japan.
  • Department of Health Promotion and Human Behavior, Kyoto University Graduate School of Medicine/School of Public Health, Kyoto, Japan.
  • Institute for Airway Disease, Hyogo, Japan.
  • Ehime University, Toon, Japan.
  • Department of Information Communication Technology ICT Division, Government of Bangladesh, Dhaka, Bangladesh.
  • Department of Computer Information Science, Higher Colleges of Technology, Abu Dhabi, United Arab Emirates.

ORCID-Profile: Shinji Inaba, Hiroshi Kawakami

Förderung

  • industrial seeds support from Ehime University
  • health care science institute

Zitieren

APA

Inaba, S., Yamamoto, K., Kaga, T., Kawakami, H., Islam, M. Z., Wannous, M., Sakata, M., Furukawa, T. A., & Yamaguchi, O. (2026). Development and initial validation of a computerized adaptive test prototype for ECG interpretation using item response theory. PLOS One, 21(7), e0344341. https://doi.org/10.1371/journal.pone.0344341

Vancouver

Inaba S, Yamamoto K, Kaga T, Kawakami H, Islam MZ, Wannous M, et al. Development and initial validation of a computerized adaptive test prototype for ECG interpretation using item response theory. PLOS One. 2026;21(7):e0344341. doi:10.1371/journal.pone.0344341

BibTeX
@article{Inaba2026,
  author = {Inaba, Shinji and Yamamoto, Kazumichi and Kaga, Tomohiro and Kawakami, Hiroshi and Islam, Mohammad Zahidul and Wannous, Muhammad and Sakata, Masatsugu and Furukawa, Toshi A and Yamaguchi, Osamu},
  title = {Development and initial validation of a computerized adaptive test prototype for ECG interpretation using item response theory},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {7},
  pages = {e0344341},
  doi = {10.1371/journal.pone.0344341}
}