A high centrifugal force-enhanced Ziehl–Neelsen method for improved detection of Mycobacterium tuberculosis
PLOS One · 02.07.2026 · 21 (7) · e0342273
DOI: 10.1371/journal.pone.0342273 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 02.07.2026. Verfasst von Godlove T Chaula und 5 weiteren Autor:innen. Beteiligte Einrichtung: Mbeya Medical Research Centre, National Institute for Medical Research, Mbeya, Tanzania. Hauptthemen laut MEDLINE: Mycobacterium tuberculosis, Tuberculosis. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European and Developing Countries Clinical Trials Partnership.
Abstract (Originalsprache)
Ziehl–Neelsen (ZN) smear microscopy remains central to tuberculosis (TB) diagnosis and treatment monitoring; however, its sensitivity is limited by incomplete recovery of Mycobacterium tuberculosis during pre-analytical processing. This study evaluated whether modifying centrifugation force and duration improves bacillary recovery and ZN smear microscopy performance. Laboratory experiments were conducted using M. tuberculosis H37Rv suspensions and clinical sputum specimens. Following NALC–NaOH treatment, samples were centrifuged at 2,000, 3,000, and 6,000 × g for 40 min. The effect of centrifugation duration was assessed at 3,000 × g by comparing 20 and 40 min using the same M. tuberculosis H37Rv cultures and the same clinical sputum specimens at both time points, ensuring paired measurements within each sample type. Smear positivity and ZN smear grading were evaluated from replicate smears and analyzed using non-parametric statistical tests, with significance set at p < 0.05. In M. tuberculosis H37Rv suspensions, no significant differences in smear positivity or grading were observed across centrifugal forces ( p = 0.368 and p = 0.212, respectively). In clinical sputum specimens, smear positivity did not differ significantly across forces ( p = 0.716), whereas ZN smear grading increased significantly with higher centrifugal force ( p = 0.0051). At 3,000 × g, extending centrifugation time from 20 to 40 min did not significantly affect smear positivity in either sample type (both p = 1.000). In contrast, ZN smear grading increased from 1+ to 2+ in clinical specimens with extended centrifugation time ( p = 0.016), while no change was observed in M. tuberculosis H37Rv suspensions. These findings indicate that increasing centrifugal force may enhance bacillary concentration in clinical sputum, resulting in improved smear grading without a corresponding increase in detection rate. Extending centrifugation time has limited impact on smear positivity. Optimization of pre-analytical centrifugation parameters may improve ZN smear microscopy performance in clinical specimens.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Mbeya Medical Research Centre, National Institute for Medical Research, Mbeya, Tanzania.
- Department of Biochemistry and Pharmacology, Mbeya Collage of Health and Allied Sciences, University of Dar es Salaam, Mbeya, Tanzania.
- School of Medicine, University of St Andrews, St. Andrews, United Kingdom.
- Department of Molecular Biology and Biotechnology, College of Natural and Applied Sciences, University of Dar es Salaam, Dar es salaam, Tanzania.
ORCID-Profile: Wilber Sabiiti, Ally Mahadhy
Förderung
- European and Developing Countries Clinical Trials Partnership
Zitieren
APA
Chaula, G. T., Namkinga, L., Sabiiti, W., Ntiningya, N. E., Mtafya, B., & Mahadhy, A. (2026). A high centrifugal force-enhanced Ziehl–Neelsen method for improved detection of Mycobacterium tuberculosis. PLOS One, 21(7), e0342273. https://doi.org/10.1371/journal.pone.0342273
Vancouver
Chaula GT, Namkinga L, Sabiiti W, Ntiningya NE, Mtafya B, Mahadhy A. A high centrifugal force-enhanced Ziehl–Neelsen method for improved detection of Mycobacterium tuberculosis. PLOS One. 2026;21(7):e0342273. doi:10.1371/journal.pone.0342273
BibTeX
@article{Chaula2026,
author = {Chaula, Godlove T and Namkinga, Lucy and Sabiiti, Wilber and Ntiningya, Nyanda E and Mtafya, Bariki and Mahadhy, Ally},
title = {A high centrifugal force-enhanced Ziehl–Neelsen method for improved detection of Mycobacterium tuberculosis},
journal = {PLOS One},
year = {2026},
volume = {21},
number = {7},
pages = {e0342273},
doi = {10.1371/journal.pone.0342273}
}
EUVIMED