EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Pneumonia and pneumothorax detection: A multi-factor evaluation of chest X-rays

Yousef Saad Aldabayan iD

PLOS One · 20.01.2026 · 21 (1) · e0341060

DOI: 10.1371/journal.pone.0341060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 20.01.2026. Verfasst von Yousef Saad Aldabayan. Beteiligte Einrichtung: Department of Respiratory Care, College of Applied Medical Sciences, King Faisal University, Al-Ahsa, Saudi Arabia. Hauptthemen laut MEDLINE: Radiography, Thoracic, Pneumothorax, Pneumonia. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deanship of Scientific Research, King Faisal University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The research creates a Vision Transformer (ViT) diagnostic system which identifies pneumonia and pneumothorax from chest radiographs through analysis of the NIH ChestX-ray14 dataset. The research methodology solves medical imaging problems through three essential components which include (i) radiograph-specific augmentation for simulating authentic imaging conditions and (ii) multi-label imbalance handling through WeightedRandomSampler with class-specific weight application to stop all-normal predictions and (iii) optimization improvements that include CosineAnnealingWarmRestarts scheduling and sigmoid-based classification head optimization and disease-specific threshold optimization. The evaluation of model performance uses AUC and sensitivity and specificity and precision and F1-score because accuracy proves ineffective when dealing with severe class imbalances. The ViT models achieve 70−75% accuracy and 0.63–0.71 AUC values for both target conditions during non-leaking and noise-aware experiments because of the weak labels and restricted supervision in the ChestX-ray14 dataset. The system enhances its ability to detect rare conditions while providing better interpretability through Vision Transformer attention-based visualization of important radiological areas. The research demonstrates that ViT performance improves significantly through medical-focused data preparation methods and training approaches which demonstrate potential for radiology assistance in high-volume and resource-constrained environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiography, ThoracicPneumothoraxPneumoniaHumansAlgorithms

Autor:innen und Institutionen

  • Department of Respiratory Care, College of Applied Medical Sciences, King Faisal University, Al-Ahsa, Saudi Arabia.

ORCID-Profile: Yousef Saad Aldabayan

Förderung

  • Deanship of Scientific Research, King Faisal University

Zitieren

APA

Aldabayan, Y. S. (2026). Pneumonia and pneumothorax detection: A multi-factor evaluation of chest X-rays. PLOS One, 21(1), e0341060. https://doi.org/10.1371/journal.pone.0341060

Vancouver

Aldabayan YS. Pneumonia and pneumothorax detection: A multi-factor evaluation of chest X-rays. PLOS One. 2026;21(1):e0341060. doi:10.1371/journal.pone.0341060

BibTeX
@article{Aldabayan2026,
  author = {Aldabayan, Yousef Saad},
  title = {Pneumonia and pneumothorax detection: A multi-factor evaluation of chest X-rays},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {1},
  pages = {e0341060},
  doi = {10.1371/journal.pone.0341060}
}
Kostenlos starten →