EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validation of deep learning enabled software MetronMind to measure vertebral heart size and vertebral left atrial size in dogs

Katharine Tess Sykes, Sonya G Gordon iD, John J Craig, Sonya Wesselowski, Alice H Watson iD

PLOS One · 2026

DOI: 10.1371/journal.pone.0339253 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift PLOS One, 2026. Verfasst von Katharine Tess Sykes und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine and Biomedical Sciences, Department of Small Animal Clinical Sciences, Texas A&M University, College Station, Texas, U…. Hauptthemen laut MEDLINE: Deep Learning, Heart Atria, Software, Heart. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Vertebral heart size (VHS) and vertebral left atrial size (VLAS) are objective radiographic measurements of heart and left atrial size, respectively and are associated with inter- and intraobserver variability when measured by humans. Artificial intelligence (AI) tools to determine VHS and VLAS have been developed and may reduce variability and save time.

Objectives

To compare two manual methods for measuring VHS and VLAS on right and left lateral canine thoracic radiographs and to compare measurements of VHS and VLAS made by deep learning-enabled program, MetronMind, with those made by a trained observer on right and left lateral radiographs. Animals Client-owned dogs (n = 1058) including 80 breeds with a variety of heart sizes, thoracic conformations and radiographic quality.

Methods

Retrospective, single-center, method-comparison study. Pearson’s correlation, Bland-Altman plots and Passing-Bablok regression were used to assess agreement.

Results

Correlation between traditional and modified manual measurements for VHS and VLAS was strong (r = 0.994 and r = 0.974, respectively), with minimal bias (−0.10 and 0.04 vertebrae, respectively) indicating that the modified methods closely approximate traditional measurements obtained from right lateral views. MetronMind measurements of VHS and VLAS from right lateral radiographs also correlated well with the human observer’s modified measurements (r = 0.947 and r = 0.811 respectively), showing small mean biases (0.08 and 0.07 vertebrae, respectively). Correlation between left and right lateral radiographic measurements of VHS (0.87 and 0.91) was higher than for VLAS (0.73 and 0.64) and bias was larger for VHS (0.26 and 0.31 vertebrae) than for VLAS (−0.13 and −0.10 vertebrae) for humans and MetronMind, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningHeart AtriaSoftwareHeartAnimalsDogsRetrospective StudiesFemaleObserver VariationOrgan Size

Autor:innen und Institutionen

  • College of Veterinary Medicine and Biomedical Sciences, Department of Small Animal Clinical Sciences, Texas A&M University, College Station, Texas, United States of America.
  • MetronMind, Paso Robles, California, United States of America.
  • Independent Academic, United Kingdom.

ORCID-Profile: Sonya G Gordon, Alice H Watson

Zitieren

APA

Sykes, K. T., Gordon, S. G., Craig, J. J., Wesselowski, S., & Watson, A. H. (2026). Validation of deep learning enabled software MetronMind to measure vertebral heart size and vertebral left atrial size in dogs. PLOS One. https://doi.org/10.1371/journal.pone.0339253

Vancouver

Sykes KT, Gordon SG, Craig JJ, Wesselowski S, Watson AH. Validation of deep learning enabled software MetronMind to measure vertebral heart size and vertebral left atrial size in dogs. PLOS One. 2026. doi:10.1371/journal.pone.0339253

BibTeX
@article{Sykes2026,
  author = {Sykes, Katharine Tess and Gordon, Sonya G and Craig, John J and Wesselowski, Sonya and Watson, Alice H},
  title = {Validation of deep learning enabled software MetronMind to measure vertebral heart size and vertebral left atrial size in dogs},
  journal = {PLOS One},
  year = {2026},
  doi = {10.1371/journal.pone.0339253}
}
Kostenlos starten →