EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bot fit: A novel approach to assessing lower limb muscular strength

Byungmun Kang, DaeEun Kim iD, Changmin Lee, Dongwoo Kim iD, Hwang-Jae Lee, Dokwan Lee, YoonMyung Kim, Hyung-Gyu Jeon, Kyunghwan Jung iD

PLOS One · 26.03.2026 · 21 (3) · e0339187

DOI: 10.1371/journal.pone.0339187 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 26.03.2026. Verfasst von Byungmun Kang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Biological Cybernetics Lab, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Muscle Strength, Lower Extremity, Exoskeleton Device. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SAMSUNG electronics, National Research Foundation of Korea, Korea Institute for Advancement of Technology (KIAT) through a grant funded by the Korea government.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces Bot Fit, an innovative hip-joint exoskeleton designed for the objective assessment of lower limb muscular strength and exercise performance. A total of 25 participants underwent baseline strength assessments using conventional fitness equipment before performing resistance exercises under two controlled conditions: a 10-second test without speed restrictions and a 30-second test at a constant speed. Bot Fit recorded motor signals and performance metrics, capturing key indicators such as repetitions and movement patterns. To analyze the relationship between muscle parameters and exercise performance, we employed correlation analysis, hierarchical cluster analysis (HCA), and regression analysis. The results demonstrated strong associations between lower limb strength and key exercises, including squats, knee-ups, and reverse lunges, particularly in short-duration and constant-speed conditions. HCA successfully clustered participants based on three exercise-related metrics with an accuracy of 0.89, while the regression model achieved a correlation coefficient of 0.86, indicating high statistical power. These findings suggest that Bot Fit provides a reliable, data-driven method for muscular strength assessment, offering valuable insights for optimizing exercise programs, preventing injuries, and enhancing physical performance. The integration of wearable robotic technology into health and fitness monitoring enables personalized exercise interventions and supports evidence-based decision-making in sports science, rehabilitation, and performance enhancement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle StrengthLower ExtremityExoskeleton DeviceHumansMaleFemaleAdultYoung AdultResistance Training

Autor:innen und Institutionen

  • Biological Cybernetics Lab, School of Electrical and Electronic Engineering, Yonsei University, Seoul, Republic of Korea.
  • Bot Fit T/F, New Business Team, Samsung Electronics, Suwon, Republic of Korea.
  • University College, Yonsei University International Campus, Incheon, Republic of Korea.
  • Sports Rehabilitation Lab, Department of Physical Education, Yonsei University, Seoul, Republic of Korea.
  • Department of Sports, Leisure, and Recreation, Soonchunhyang University, Chungnam, Republic of Korea.

ORCID-Profile: DaeEun Kim, Dongwoo Kim, Kyunghwan Jung

Förderung

  • SAMSUNG electronics
  • National Research Foundation of Korea
  • Korea Institute for Advancement of Technology (KIAT) through a grant funded by the Korea government

Zitieren

APA

Kang, B., Kim, D., Lee, C., Kim, D., Lee, H. J., Lee, D., Kim, Y., Jeon, H. G., & Jung, K. (2026). Bot fit: A novel approach to assessing lower limb muscular strength. PLOS One, 21(3), e0339187. https://doi.org/10.1371/journal.pone.0339187

Vancouver

Kang B, Kim D, Lee C, Kim D, Lee HJ, Lee D, et al. Bot fit: A novel approach to assessing lower limb muscular strength. PLOS One. 2026;21(3):e0339187. doi:10.1371/journal.pone.0339187

BibTeX
@article{Kang2026,
  author = {Kang, Byungmun and Kim, DaeEun and Lee, Changmin and Kim, Dongwoo and Lee, Hwang-Jae and Lee, Dokwan and Kim, YoonMyung and Jeon, Hyung-Gyu and Jung, Kyunghwan},
  title = {Bot fit: A novel approach to assessing lower limb muscular strength},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {3},
  pages = {e0339187},
  doi = {10.1371/journal.pone.0339187}
}
Kostenlos starten →