EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Carbon footprint comparison of video intubation tools: Disposable laryngoscopes, reusable laryngoscopes, and stylets

Danyang Pan, Yating Yang, Sirui Chen, Jinhe Deng, Gaofeng Zhao iD, Min Zhong

PLOS One · 2025

DOI: 10.1371/journal.pone.0339058 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS One, 2025. Verfasst von Danyang Pan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China. Hauptthemen laut MEDLINE: Carbon Footprint, Disposable Equipment, Laryngoscopes, Intubation, Intratracheal. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

As healthcare systems grapple with their 5% global carbon footprint contribution, sustainable medical device selection emerges as a critical decarbonization lever. This life cycle assessment (LCA) quantifies environmental disparities among three prevalent video intubation tools—Disposable video laryngoscopes (VLs), reusable VLs, and video Stylets—to guide evidence-based procurement.

Methods

Using International Organization for Standardization (ISO)14040 compliant life cycle assessment (LCA) methodology—the international standard defining LCA principles and framework—we quantified cradle-to-grave emissions for three video intubation devices manufactured by Zhejiang UE Medical Corp. The functional unit (one tracheal intubation) incorporated material extraction, manufacturing, low-temperature LTPS/ HLD, transportation, and disposal. SimaPro 9.4.0 with Ecoinvent 3.8 database calculated CO₂ equivalents (kg CO₂e), validated through sensitivity analyses of sterilization loading (10–80 devices/cycle) and regional grids.

Results

The HLD-disinfected video stylet demonstrated superior environmental performance, emitting 98.24 kg CO₂e per 500 procedures—45.8% and 42.0% lower than reusable VLs (181.45 kg CO₂e) and disposable VLs (169.47 kg CO₂e), respectively. Sensitivity analyses identified sterilization loading as the dominant variable: half-load (50% chamber utilization) reduced emissions by 89–91% versus single-device processing, with full-load optimization yielding incremental 11–14% reductions. Process and regional variability further revealed that HLD decreased emissions by 19–24% compared to LTPS, while grid carbon intensity caused 24–33% variability (India vs. EU). Scenario comparisons confirmed the video stylet’s environmental dominance across sterilization methods—even with LTPS (349.99 kg CO₂e/500 uses), it maintained a 45% reduction over reusable VL baselines, whereas HLD-treated video stylets (94.32 kg CO₂e) showed 6.7-fold lower emissions than disposable VLs and 59% below HLD-reprocessed reusable VLs.

Conclusions

HLD-reprocessed video stylets are the environmentally optimal choice for high-volume, low-infection-risk settings. For low-throughput or high-risk scenarios, providers should balance environmental impacts with clinical requirements through frequency and resource assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon FootprintDisposable EquipmentLaryngoscopesIntubation, IntratrachealEquipment ReuseHumans

Autor:innen und Institutionen

  • Department of Anesthesiology, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China.
  • School of Civil and Transportation Engineering, Guangdong University of Technology, Guangzhou, Guangdong, China.
  • Satate Key Laboratory of Traditional Chinese Medicine Syndrome, Guangzhou, Guangdong, China.

ORCID-Profile: Gaofeng Zhao

Zitieren

APA

Pan, D., Yang, Y., Chen, S., Deng, J., Zhao, G., & Zhong, M. (2025). Carbon footprint comparison of video intubation tools: Disposable laryngoscopes, reusable laryngoscopes, and stylets. PLOS One. https://doi.org/10.1371/journal.pone.0339058

Vancouver

Pan D, Yang Y, Chen S, Deng J, Zhao G, Zhong M. Carbon footprint comparison of video intubation tools: Disposable laryngoscopes, reusable laryngoscopes, and stylets. PLOS One. 2025. doi:10.1371/journal.pone.0339058

BibTeX
@article{Pan2025,
  author = {Pan, Danyang and Yang, Yating and Chen, Sirui and Deng, Jinhe and Zhao, Gaofeng and Zhong, Min},
  title = {Carbon footprint comparison of video intubation tools: Disposable laryngoscopes, reusable laryngoscopes, and stylets},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0339058}
}
Kostenlos starten →