EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydrodynamic instabilities in membrane systems with current loading, Fourier analysis

Sławomir Grzegorczyn iD, Paweł Dolibog, Iwona Dylong, Andrzej Ślęzak

PLOS One · 04.05.2026 · 21 (5) · e0335005

DOI: 10.1371/journal.pone.0335005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, online erschienen am 04.05.2026. Verfasst von Sławomir Grzegorczyn und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Zabrze, Poland. Hauptthemen laut MEDLINE: Hydrodynamics, Membranes, Artificial, Cell Membrane. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ÅšlÄ…ski Uniwersytet Medyczny w Katowicach.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Time-current characteristics for membrane systems with bacterial cellulose membranes located in horizontal plane and with NaCl solutions, indicate a stable formation of concentration boundary layers near the membrane for the configuration with a solution of lower concentration and lower density above the membrane (A). In turn, for the configuration with a higher concentration above the membrane (B) and a sufficiently large initial concentration quotient on the membrane (( C h / C l ) o ) current pulsations are observed over time, resulting from hydrodynamic instabilities occurring in the vicinity of the membrane. The increase of ( C h / C l ) o in configuration B causes an increase in the frequency of current pulsations and a change in their amplitudes. Furthermore, significant differences were observed between the types of the temporal changes in membrane currents in both configurations. The currents measured in steady states after 24 hours show differences between A and B configurations for ( C h / C l ) o > 500. Fast Fourier Transform (FFT) used to analyze the hydrodynamic instabilities in the range of observed pulsations of the measured currents shows that the average signal power of currents in the frequency range from 0.05 to 1 min -1 , depends non-linearly on the initial concentration quotient on the membrane, showing a maximum for the ( C h / C l ) o equal to 2500. In turn, the Short Time Fourier Transform (STFT) applied to the current signal as well as to the current difference signal (time lag equal to 1 min.) showed better resolution of the hydrodynamic instability analysis for the current difference signal. The increase of ( C h / C l ) o in the membrane system causes a gradual increase in STFT amplitudes towards longer times and higher frequencies. In turn, significant activity of hydrodynamic instabilities was observed in the first 50 min of current measurements for ( C h / C l ) o > 2500, followed by suppression of these instabilities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrodynamicsMembranes, ArtificialCell MembraneFourier AnalysisCellulose

Substanzen

Membranes, ArtificialCellulose

Autor:innen und Institutionen

  • Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia, Zabrze, Poland.
  • Department of Healt Sciences and Physiotherapy, Collegium Medicum, Jan Dlugosz University, Częstochowa, Poland.

ORCID-Profile: Sławomir Grzegorczyn

Förderung

  • ÅšlÄ…ski Uniwersytet Medyczny w Katowicach

Zitieren

APA

Grzegorczyn, S., Dolibog, P., Dylong, I., & Ślęzak, A. (2026). Hydrodynamic instabilities in membrane systems with current loading, Fourier analysis. PLOS One, 21(5), e0335005. https://doi.org/10.1371/journal.pone.0335005

Vancouver

Grzegorczyn S, Dolibog P, Dylong I, Ślęzak A. Hydrodynamic instabilities in membrane systems with current loading, Fourier analysis. PLOS One. 2026;21(5):e0335005. doi:10.1371/journal.pone.0335005

BibTeX
@article{Grzegorczyn2026,
  author = {Grzegorczyn, Sławomir and Dolibog, Paweł and Dylong, Iwona and Ślęzak, Andrzej},
  title = {Hydrodynamic instabilities in membrane systems with current loading, Fourier analysis},
  journal = {PLOS One},
  year = {2026},
  volume = {21},
  number = {5},
  pages = {e0335005},
  doi = {10.1371/journal.pone.0335005}
}
Kostenlos starten →