Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Zhen Zhao und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Hydraulic and Electric Power, Heilongjiang University, Harbin, China. Hauptthemen laut MEDLINE: Agricultural Irrigation, Bionics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Basic Scientific Research Fund of Heilongjiang Provincial Universities.
Abstract (Originalsprache)
The blockage inside the flow channel of drip irrigation emitters is a key issue that restricts their usability. The low-speed vortex zone that exists in traditional channel design is the core reason. This study designed four different structures of pit bionic drip irrigation emitters based on the principles of plant bionics. The computational fluid dynamics (CFD) numerical simulation method was adopted and the flow velocity and turbulence energy of four structures were analyzed. The discrete element method (DEM) was combined to study the motion trajectory of 0.1 mm sand particles. The results indicate that schemes 1, 2, and 4 all have significant low-speed vortices in the return water zone (D zone). The situation in scheme 3 is relatively mild and the probability of sand particles depositing in the channel decreases. The flow channel structure was further optimized based on the original foundation and eight types of sand particles with different sizes were selected for anti clogging experiments. The relative traffic of the optimized model in the third and fourth stages was 13.34% and 14.51% higher. In terms of the sensitive particle size causing blockage, the maximum allowable particle size of the optimized flow channel structure was nearly twice that of scheme 3. When the particle size was 0.120, 0.165, 0.187, 0.212, and 0.245 mm, the sedimentation rate was reduced by an average of 58.02%. This study confirms that optimized drip irrigation emitters have better anti clogging performance under multiple particle size drip irrigation conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Hydraulic and Electric Power, Heilongjiang University, Harbin, China.
- Heilongjiang Academy of Black Soil Conservation and Utilization, Harbin, China.
ORCID-Profile: Tianyu Xu
Förderung
- the Basic Scientific Research Fund of Heilongjiang Provincial Universities
Zitieren
APA
Zhao, Z., Xu, T., Su, Y., Bao, S., & Yu, Q. (2025). Structural optimization of pit bionic drip irrigation emitter to improve hydraulic performance and anti-clogging performance. PLOS One. https://doi.org/10.1371/journal.pone.0334698
Vancouver
Zhao Z, Xu T, Su Y, Bao S, Yu Q. Structural optimization of pit bionic drip irrigation emitter to improve hydraulic performance and anti-clogging performance. PLOS One. 2025. doi:10.1371/journal.pone.0334698
BibTeX
@article{Zhao2025,
author = {Zhao, Zhen and Xu, Tianyu and Su, Yanru and Bao, Sanlin and Yu, Qiuyue},
title = {Structural optimization of pit bionic drip irrigation emitter to improve hydraulic performance and anti-clogging performance},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0334698}
}
EUVIMED