Dual-resonance optical fiber lossy mode resonance refractive index sensor
PLOS One · 2025
DOI: 10.1371/journal.pone.0334249 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Xupeng Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, The Second Hospital of Tianjin Medical University, Tianjin, China. Hauptthemen laut MEDLINE: Optical Fibers, Refractometry, Fiber Optic Technology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In this paper, we propose a dual-channel surface refractive index sensor based on optical fiber lossy mode resonance (LMR). A multilayer transmission matrix model is constructed to simulate and analyze the optical fiber LMR effect based on two semiconductor oxides, SnO 2 and TiO 2 . Through the rational design of structural parameters, we successfully realize the coexistence of mutually independent LMRs on a single fiber, thereby enabling dual-channel sensing. The dual-channel optical fiber LMR sensor was prepared by electrostatically assembling TiO 2 nanofilms and SnO 2 nanofilms on the sidewall of the optical fiber. The refractive index sensitivity of the dual-channel optical fiber LMR was evaluated via wavelength interrogation, achieving dual-channel refractive index sensing. The refractive index sensitivities are 538.422 nm/RIU and 615.647 nm/RIU in the range of 1.3350 ~ 1.3742. The dual-channel optical fiber LMR refractometer designed in this investigation is a promising platform for the simultaneous detection of multiple protein species and heavy metal ions in biochemical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Urology, The Second Hospital of Tianjin Medical University, Tianjin, China.
- Tianjin Institute of Urology, The Second Hospital of Tianjin Medical University, Tianjin, China.
- Department of Urology, Jincheng People's Hospital, Shanxi, China.
- School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin China.
ORCID-Profile: Xupeng Wu
Zitieren
APA
Wu, X., Dai, X., Wang, J., Ren, H., & Wang, X. (2025). Dual-resonance optical fiber lossy mode resonance refractive index sensor. PLOS One. https://doi.org/10.1371/journal.pone.0334249
Vancouver
Wu X, Dai X, Wang J, Ren H, Wang X. Dual-resonance optical fiber lossy mode resonance refractive index sensor. PLOS One. 2025. doi:10.1371/journal.pone.0334249
BibTeX
@article{Wu2025,
author = {Wu, Xupeng and Dai, Xiaoshuang and Wang, Jian and Ren, Haipeng and Wang, Xu},
title = {Dual-resonance optical fiber lossy mode resonance refractive index sensor},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0334249}
}
EUVIMED