Physiological responses to full and segmented duet routines in elite artistic swimmers
PLOS One · 2025
DOI: 10.1371/journal.pone.0333791 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Xavier Iglesias und 6 weiteren Autor:innen. Beteiligte Einrichtung: Grup de Recerca en Ciències de l'Esport INEFC Barcelona (GRCEIB), Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona …. Hauptthemen laut MEDLINE: Swimming, Athletes. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Consejo Superior de Deportes, Institut Català de les Dones, Institut Nacional d'Educació FÃsica de Catalunya.
Abstract (Originalsprache)
Artistic swimming combines prolonged breath-hold periods with high-intensity movements, resulting in unique physiological demands. Direct measurement of key variables such as oxygen uptake (VO₂) during routines is limited by frequent immersion. However, VO₂ monitoring is essential for understanding the balance between aerobic and anaerobic energy contributions, guiding training strategies and reducing injury risk. This study aimed to analyze the acute physiological responses, VO₂, blood lactate concentration, and heart rate, during free duet routines in elite artistic swimmers, using a segmented protocol that emphasized the two longest apneas. Sixteen elite artistic swimmers performed both complete and segmented versions of the routine. VO₂ was estimated using retro-extrapolation, while lactate was measured after each phase, and heart rate was continuously monitored. The protocol included six measurement points: pre-routine, pre- and post-apnea 1 and 2, and post-routine. VO₂ increased rapidly, reaching nearly 90% of VO₂ peak within 67 seconds (mean: 61.8 ± 15.1 mL·min ⁻ ¹·kg ⁻ ¹). Blood lactate concentration rose progressively, peaking at 5.93 ± 1.41 mmol·L ⁻ ¹. Heart rate exhibited large fluctuations, with a maximum of 203.8 ± 5.0 beats·min ⁻ ¹ and a minimum of 71.9 ± 16.6 beats·min ⁻ ¹, reflecting a bradycardic response during apneas. No significant changes were observed in VO₂ or lactate between pre- and post-apnea values, as measured around the two longest apneas within the routine. These findings suggest that, under the specific conditions of this study, short-duration apneas (< 20 s) may be insufficient on their own to elicit distinct physiological shifts. However, the progressive increases observed in blood lactate and heart rate throughout the full routine suggest that the overall physiological load may be influenced more by sustained exercise intensity and the cumulative effect of repeated apneas than by isolated breath-hold events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Grup de Recerca en Ciències de l'Esport INEFC Barcelona (GRCEIB), Institut Nacional d'Educació Física de Catalunya (INEFC), Universitat de Barcelona (UB), Barcelona, Spain.
- School of Health and Medical Sciences, Division of Sport Sciences, Örebro University, Örebro, Sweden.
ORCID-Profile: Xavier Iglesias, Ignacio Fernández-Jarillo
Förderung
- Consejo Superior de Deportes
- Institut Català de les Dones
- Institut Nacional d'Educació FÃsica de Catalunya
Zitieren
APA
Iglesias, X., Rodríguez-Zamora, L., Carrasco-Marginet, M., Irurtia, A., Rodríguez, F. A., Fernández-Jarillo, I., & Chaverri, D. (2025). Physiological responses to full and segmented duet routines in elite artistic swimmers. PLOS One. https://doi.org/10.1371/journal.pone.0333791
Vancouver
Iglesias X, Rodríguez-Zamora L, Carrasco-Marginet M, Irurtia A, Rodríguez FA, Fernández-Jarillo I, et al. Physiological responses to full and segmented duet routines in elite artistic swimmers. PLOS One. 2025. doi:10.1371/journal.pone.0333791
BibTeX
@article{Iglesias2025,
author = {Iglesias, Xavier and Rodríguez-Zamora, Lara and Carrasco-Marginet, Marta and Irurtia, Alfredo and Rodríguez, Ferran A and Fernández-Jarillo, Ignacio and Chaverri, Diego},
title = {Physiological responses to full and segmented duet routines in elite artistic swimmers},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0333791}
}
EUVIMED